NOTE
”Extra hot water” usually means that the electrical
addition has been activated and therefore increases
the electrical consumption.
”Extra hot water” can be activated in three different
ways:
1. Periodic time based extra hot water
Interval between increases is selected in menu 1.7.
Menu 1.8 shows when the next increase is due.
The increased temperature is maintained by the
electrical addition for one hour.
2. Schedule time based extra hot water
The start and stop times for the day of the week that
the increase is required are set in the sub menus for
menu 7.4.0.
The increased temperature is maintained by the
electrical addition for the selected period.
3. Temporary extra hot water
The current ”extra hot water” mode is shown on the
display (A) when the button is pressed and by
pressing the button again the mode changes
between 3 hours and standby mode.
The increased temperature is maintained by the
electrical addition until the period of time has ex-
pired.