54
Subject to change without notice | 83053700lUK | ait-deutschland GmbH
L
/2.15
N
/2.15
PE
/2.15
L
-X0
N PE L
-X0
L L
MOT
-X2.
ASD
EVU
-K10
MOT
External flow rate switch; bridge if no switch is connected.
Legend:
Energy supplier contact; closed on release; bridge if no blocking intervalEVU
Operating materials
ASD
K10 Controller board; Attention: I-max = 6A/230VAC
MOT
UK817380a
EVU
Connection of external motor protection; bridge if no external motor protection is connected.
ASD
Function
27.01.2014
PEP 007/2011
3
Achim Pfleger
10X616; 10X617;
10X619;
-
3/3
Achim Pfleger 23.05.2011
SWP 581 - 691; 561H
817380
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
a ÄM 070/2013
Bl von Anz
Name
Datum
Zustand
Blatt-Nr.
Bearb.
Datum
Änderung
SWP 581 / SWP 691 / SWP 561H Circuit diagram 3/3