EasyManua.ls Logo

Alpha 41 532 05 - Technical Data

Alpha 41 532 05
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
Heat input gross - CH kW
Heat input net - CH kW
Heat output condensing (50/30°C) - CH kW
Heat output non condensing (80/60°C) CH kW
Heat output min. - CH kW
Gas rate at max. output m³/h
Gas supply pressure mbar
Max. CH temperature °C
Gas burner injector diameter mm
Differential burner pressure - min. mbar
Differential burner pressure - CH mbar
NOx Class
Factory set CO
2
(± 0.25%)
CO
2
at maximum CH output %
CO
2
at minimum CH output %
CO weight (nominal) mg/kWh
CO (max) ppm
Maximum CO/CO
2
Ratio
SAP/SEDBUK seasonality efficiency 2005 %
SAP/SEDBUK seasonality efficiency 2009 %
Max. primary system pressure bar
Min. primary system pressure bar
Recommended system pressure - Cold bar
Electrical power consumption - Max. Watts
Electrical power consumption - Standby Watts
2 TECHNICAL DATA
Alpha CD13R, 18R, 24R - Technical Data
26.6
24.0
25.6
23.5
6.5
2.54
20
82
5.25
0.6
1.45
5
9.2
9.0
27
200
0.003
90.3
88.6
2.5
0.5
1.0
55
6
2.1 TECHNICAL PERFORMANCE DATA - NATURAL GAS (Cat I2H 2H - G20 20 mbar)
CD 13R CD 18R CD24R
13.8
12.4
13.1
12.1
5.4
1.31
20
82
5.1
0.4
1.7
5
9.2
9.0
16
200
0.003
90.1
88.5
2.5
0.5
1.0
55
6
20.4
18.4
19.6
18.0
5.4
1.94
20
82
5.1
0.4
3.54
5
9.2
9.0
25
200
0.003
90.1
88.4
2.5
0.5
1.0
55
6

Related product manuals