6. GAS LEAK
If a fault or gas leak is suspected, turn off the gas supply. Do not touch any electrical switches, do not smoke and extinguish
all naked flames. Contact your local Gas Region immediately.
7. ELECTRICAL SUPPLY
The boiler requires a 230/240 V ~ 50 Hz supply, fused at 3 A if a 13 A 3-pin plug is used or a 5 A fuse if any other type of plug
is used.
To connect a plug:-
The colour of the wires in the mains lead of the boiler may not correspond with the coloured markings identifying the
terminals in your plug. In this case proceed as follows:-
The wire coloured green and yellow must be connected to the terminal in the plug that is marked with the letter E, or by the
earth symbol
, or coloured green or green and yellow.
The blue wire must be connected to the terminal which is marked with either the letter N or coloured black.
The brown wire must be connected to the terminal which is marked with the letter L or coloured red.
THE APPLIANCE MUST BE EARTHED.
7 GAS SAFETY REGULATIONS
If you experience a problem of no heating, try to solve the problem by following the simple checks below before calling out a
service engineer.
If applicable, pull the controls panel cover forward and down to gain access to the controls.
8 FAULT FINDING FOR THE USER
Current Gas Safety (Installation and Use) Regulations:-
It is the law that all gas appliances are installed and serviced by a competent person, i.e. Gas Safe registered personnel.
Failure to install or service appliances correctly could lead to prosecution. It is in your interest and that of safety to ensure
compliance with the law. The manufacturer's instructions must not be taken in any way as over-riding statutory obligations.
The Benchmark Checklist must be fully completed by the installer on installation of the boiler. The Benchmark Checklist is
shown in back of the Installation and Servicing instructions. All Gas Safe registered installers carry a Gas Safe ID card and
have a registration number. Both should be recorded in the Checklist. You can check your installer is Gas Safe registered by
calling Gas Safe on 0800 408 5500.
A
B
C
- Check that the electrical supply to the boiler is on. If so
- Check that all controls are calling for heat, i.e. room thermostat, clock. If so
- Check that the gas supply is on. If the light continues to come on after resetting
Ring the
Alpha Helpline Service
Tel: 0844 8718764
You will be asked
the Serial No. of your
boiler when you ring.
The Serial No. is located
on the underside of
the boiler.
If any of these lights are on or flashing,
rotate the selector switch to RESET (position 3)
See C
Turn to
maximum
Two channel clock
(if fitted)
Turn selector to (position 2)ON
If this light is not on
See A
This light should illuminate
If not - See B
0
1
2
3
1
2
3
4
5
6
7
8
9
RESET
ON
OFF
FROST
A
D
B
C
SELECTOR THERMOSTAT
CD18R
3
Alpha CD13R, 18R, 24R