Preface
1
Preface
Thank you for buying AS600M series driver made by ShenZhen ALPHA Inverter
Co.,Ltd.
This series of drivers adopt the closed-loop vector control technology that features
precision speed control, high torque at low frequency and load capacity strongly. The
revised weak magnetic algorithm makes the divers have qucik reponse on high speed
area with the great load inertia, which can provide high-performance speed and
position servo function for your equipments.Its powerful function and simple operation
are easy to achieve the high precision turning,milling,spindle position control,
rigidity
tapping, thread cutting and so on.
This series of drivers have wide speed range, quick responsehigh torque at low
frequency and position tracking. They apply to most motor drive applications,
including the numerical control lathe, processing center, CNC milling machine, CNC
boring machine, and other fields such as textile industry, plastic industry, carton
packaging industry, woodworking machinery and so on.
If you have any problem that can’t be solved in operation, please contact the nearest
local agents, or contact our company directly.
The instruction manual must be made avaible to the user. Prior to performing any work
on the unit the user must familiarize himself with the unit. This especially applies to the
knowledge and observance of the following safety and warning indications. The used
pictograms have following significance.

Table of Contents

Questions and Answers

  • R
    Rebecca ColemanSep 12, 2025
    What to do if Alpha AS600M DC Drives show output earthing?
    • C
      Connor GraySep 12, 2025
      If your Alpha DC Drives are showing output earthing, check whether the motor insulation has become poor if the output earthing current exceeds the specified value. Also, check whether the connection line between the driver and the motor is damaged.
  • L
    Lance WhiteSep 12, 2025
    How to check for load short-circuit or output earthing short-circuit in Alpha AS600M?
    • A
      Amy PetersonSep 13, 2025
      To check for a load short-circuit or output earthing short-circuit in Alpha DC Drives, verify whether the connection cable between the driver and the motor is damaged if the driver output load is short-circuited. If the output side earthing is short-circuited, check the motor coil resistance and the motor insulation.
  • S
    Steven HowardSep 15, 2025
    How do I fix an external fault with RS485 serial communication on Alpha AS600M DC Drives?
    • J
      Joshua ThorntonSep 15, 2025
      To fix an external fault with RS485 serial communication on Alpha DC Drives, set the correct timeout detection time or set the Pb.03 timeout detection time as 0.0s if there is a serial (MODBUS) transmission error. Check the external control circuit if the fault is caused by it. Check the input terminal conditions. If terminals are not used but the fault is still displayed, please seek the technical support for settlement.

Summary

Chapter 1 Purchase Inspection

Chapter 2 Installation and Wiring

2.4 Main Circuit Wiring

Detailed instructions for connecting the main power and motor circuits to the driver.

2.5 Control Circuit Connection

Guidance on wiring the control signals and communication interfaces for the driver.

Chapter 3 Operation

Chapter 4 Parameter Index

P0: Basic Function

Detailed parameters for the basic functions of the AS600M driver.

P3: I; O Terminal Control

Parameters for configuring input/output terminals and communication settings.

P4: Analog and Pulse Input and Output Terminals

Parameters for analog and pulse signal inputs and outputs.

PA: Motor Parameters

Parameters for configuring motor characteristics and settings.

Pb: MODBUS Communication

Parameters for configuring communication via the MODBUS protocol.

Pd: Protection and Fault Parameters

Parameters for driver protection features and fault handling.

Chapter 5 Detailed Function Introduction

5.2 I;O Terminal Ctrl

Configuration and control of input/output terminals for various functions.

Chapter 6 Troubleshooting

6.1 Troubleshooting

Guide to identifying and resolving common faults, error codes, and protection states.

6.2 Warning Display and Explanation

Explains warning codes, their meaning, and how the driver behaves during warnings.

6.3 Motors Faults and Corrective Measure

Troubleshooting guide for common motor faults and their corrective actions.

Chapter 7 Peripheral Equipment

Chapter 8 Maintenance

8.1 Inspection and Maintenance

Procedures for routine inspection and maintenance to ensure driver reliability.

Appendix 2 Use of MODBUS Communication

Constitution of MODBUS Communication

Overview of setting up a MODBUS communication network with multiple drivers.

Communication Standard

Technical details of the RS-485 communication interface and parameters.

Setting of Communication Parameters

Instructions for setting communication parameters via the keypad.

Command Code

Description of supported MODBUS command codes and their functions.

List of Abnormality Codes

Explains the meaning of various abnormality codes encountered during MODBUS communication.

Appendix 3 Driver Warranty Card

Alpha AS600M Series Specifications

General IconGeneral
Cooling MethodForced air cooling
Output Current600A
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short circuit
Communication InterfaceModbus RTU
Storage Temperature-20°C to 60°C
Relative Humidity5% to 95% (non-condensing)