Alpha Evoke 28 and 33 - Error Codes and Fault Finding
Error
code
Fault Fault description Possible causes
Service reminderSr Service reminder count down (0 - 36 months) has
reached zero
See Section 6.13, parameter P6
Note: E97 is also shown on Climatic controller,
if used
Note: The 'Sr' code will not stop the boiler
functioning
Note: Pressing the RESET button will clear the
'Sr' code for 24 hrs to allow the display to be
read
To permanently reset the error 'Sr' / E97
1. Enter the parameter menu using the
password 69. See Section 6.13.
2. Parameter P6 will show 0.
3. Set P6 to any value above zero, save by
pressing the mode button (
) and wait
for '88' to be displayed as confirmation.
4. Then set P6 to 0, save by pressing the mode
button ( ) and wait for '88' to be
displayed as confirmation.
5. Now set the parameter P6 at the number
of months to the next service reminder
(i.e. 12 for one year). Save by pressing the
mode button (
) and wait for '88' to be
displayed as confirmation.