Alpha Evoke 28NX and 33NX - Energy Classification
12 ENERGY CLASSIFICATION
The values in the following tables refer to the maximum heating output.
Model(s): Evoke 28NX
Condensing boiler: YES
Low-temperature boiler: NO
B1 boiler: NO
Cogeneration space heater: NO Equipped with a supplementary heater: NO
Combination heater: YES
Item Symbol Value Unit Item Symbol Value Unit
Rated heat output P
n
24 kW
Seasonal space heating energy
efficiency
η
s
94 %
For boiler space heaters and boiler combination heaters: useful
heat output
For boiler space heaters and boiler combination heaters: Useful
efficiency
At rated heat output and high
temperature regime (*)
P
4
24.0 kW
At rated heat output and high
temperature regime (*)
η
4
87.8 %
At 30% of rated heat output and low
temperature regime (**)
P
1
8.05 kW
At 30% of rated heat output and low
temperature regime (**)
η
1
98.7 %
Auxiliary electricity consumption Other items
At full load el
max
0.012 kW Standby heat loss P
stby
0.054 kW
At part load el
min
0.006 kW Ignition burner power consumption P
ign
0.000 kW
In standby mode P
SB
0.002 kW Emissions of nitrogen oxides NO
X
34.9
mg /
kWh
For combination heaters:
Declared load profile XL Water heating energy efficiency η
WH
87 %
Daily electricity consumption Q
elec
0.109 kWh Daily fuel consumption Q
fuel
22.5 kWh
Contact details Alpha Therm Ltd., Nepicar House, Wrotham Heath, Kent. TN15 7RS
(*) High temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30°C, for low-temperature boilers 37°C and for other heaters 50°C return temperature.
Model(s): Evoke 33NX
Condensing boiler: YES
Low-temperature boiler: NO
B1 boiler: NO
Cogeneration space heater: NO Equipped with a supplementary heater: NO
Combination heater: YES
Item Symbol Value Unit Item Symbol Value Unit
Rated heat output P
n
28 kW
Seasonal space heating energy
efficiency
η
s
94 %
For boiler space heaters and boiler combination heaters: useful
heat output
For boiler space heaters and boiler combination heaters: Useful
efficiency
At rated heat output and high
temperature regime (*)
P
4
28.0 kW
At rated heat output and high
temperature regime (*)
η
4
87.9 %
At 30% of rated heat output and low
temperature regime (**)
P
1
9.4 kW
At 30% of rated heat output and low
temperature regime (**)
η
1
98.8 %
Auxiliary electricity consumption Other items
At full load el
max
0.013 kW Standby heat loss P
stby
0.054 kW
At part load el
min
0.006 kW Ignition burner power consumption P
ign
0.000 kW
In standby mode P
SB
0.002 kW Emissions of nitrogen oxides NO
X
30.7
mg /
kWh
For combination heaters:
Declared load profile XL Water heating energy efficiency η
WH
87 %
Daily electricity consumption Q
elec
0.120 kWh Daily fuel consumption Q
fuel
22.5 kWh
Contact details Alpha Therm Ltd., Nepicar House, Wrotham Heath, Kent. TN15 7RS
(*) High temperature regime means 60°C return temperature at heater inlet and 80°C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30°C, for low-temperature boilers 37°C and for other heaters 50°C return temperature.
12.1 TECHNICAL PARAMETERS FOR MIXED BOILERS (IN COMPLIANCE WITH REGULATION 811/2013)