EasyManua.ls Logo

Alstom MX3EG1A - Page 30

Alstom MX3EG1A
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
pag. 29
MDE/A133 2295 001
MX3EG1A
WARNING:
Factory settings may prove not to suit the plant. Therefore, the device must be
configured anew on installation.
SPARE
O
N
O
F
F
V
A
L
U
E
/
/
/
100.0 V
100.0 V
0.30 s
0.10 s
1
2.00 s
15 min
0.2 s
2 %
15 %
4 %
80 %
NORM
0.10 Hz
5 %
10 °
X
0.02 Ubn
PULSE
0.20 s
2.00 s
30.00 s
X
0.50 s
CONT
0.20 s
2.00 s
6000 V
6000 V
/
/
/
/
/
/
TABLE OF SETTINGS
D
E
S
C
R
I
P
T
I
O
N
F
U
N
C
T
I
O
N
M
A
I
N
O
N
O
F
F
V
A
L
U
E
r
a
t
e
d
f
r
e
q
u
e
n
c
y
f
n
5
0
H
z
b
a
r
r
a
t
e
d
v
o
l
t
a
g
e
U
b
n
1
0
0
.
0
V
g
e
n
e
r
a
t
o
r
r
a
t
e
d
v
o
l
t
a
g
e
U
g
n
1
0
0
.
0
V
c
l
o
s
i
n
g
p
u
l
s
e
t
i
m
e
t
c
0
.
3
0
s
b
r
e
a
k
e
r
c
l
o
s
i
n
g
t
i
m
e
t
r
0
.
1
0
s
max. number of parallel sequence attempts
Ns
1
closing interval min. time
twc
2.00 s
p
a
r
a
l
l
e
l
s
e
q
u
e
n
c
e
m
a
x
.
t
i
m
e
t
s
1
5
m
i
n
s
t
a
b
i
l
i
t
y
t
i
m
e
t
d
0
.
2
s
max. deviation bar frequency/rated frequency
D
f
b
(
±
)
2
%
max. deviation generator frequency/rated frequency
D
f
g
(
±
)
1
5
%
max. deviation bar voltage/rated voltage
b
(
±
)
4
%
m
i
n
.
g
e
n
e
r
a
t
o
r
v
o
l
t
a
g
e
/
r
a
t
e
d
v
o
l
t
a
g
e
D
U
g
8
0
%
l
i
v
e
b
a
r
m
o
d
e
(
L
B
)
L
B
N
O
R
M
m
a
x
.
f
r
e
q
u
e
n
c
y
d
i
f
f
e
r
e
n
c
e
D
f
(
±
)
0
.
1
0
H
z
m
a
x
.
v
o
l
t
a
g
e
d
i
f
f
e
r
e
n
c
e
D
U
(
±
)
5
%
m
a
x
.
p
h
a
s
e
d
i
f
f
e
r
e
n
c
e
D
p
(
±
)
1
0
°
d
e
a
d
b
a
r
m
o
d
e
(
D
B
)
D
B
X
d
e
a
d
b
a
r
l
e
v
e
l
U
d
0
.
0
2
U
b
n
frequency regulation mode
CP
f
PULSE
f
r
e
q
u
e
n
c
y
r
e
g
u
l
a
t
i
o
n
p
u
l
s
e
t
i
m
e
t
f
p
u
0
.
2
0
s
f
r
e
q
u
e
n
c
y
r
e
g
u
l
a
t
i
o
n
m
i
n
.
p
a
u
s
e
t
i
m
e
t
f
p
a
2
.
0
0
s
f
r
e
q
u
e
n
c
y
r
e
g
u
l
a
t
i
o
n
m
a
x
.
p
a
u
s
e
t
i
m
e
t
f
p
m
3
0
.
0
0
s
l
o
a
d
p
u
l
s
e
m
o
d
e
L
P
X
l
o
a
d
p
u
l
s
e
t
i
m
e
t
l
p
0
.
5
0
s
voltage regulation mode
CP
U
CONT
v
o
l
t
a
g
e
r
e
g
u
l
a
t
i
o
n
p
u
l
s
e
t
i
m
e
t
u
p
u
0
.
2
0
s
v
o
l
t
a
g
e
r
e
g
u
l
a
t
i
o
n
m
i
n
.
p
a
u
s
e
t
i
m
e
t
u
p
a
2
.
0
0
s
b
a
r
p
r
i
m
a
r
y
r
a
t
e
d
v
o
l
t
a
g
e
U
b
T
V
6
0
0
0
V
g
e
n
e
r
a
t
o
r
p
r
i
m
a
r
y
r
a
t
e
d
v
o
l
t
a
g
e
U
g
T
V
6
0
0
0
V
o
s
c
i
l
l
o
p
e
r
t
u
r
b
o
g
r
a
p
h
y
t
r
i
g
g
e
r
S
I
N
C
.
O
K
o
s
c
i
l
l
o
p
e
r
t
u
r
b
o
g
r
a
p
h
t
p
r
e
t
r
i
g
g
e
r
t
i
m
e
2
s
s
e
t
t
i
n
g
s
i
n
u
s
e
:
M
A
I
N
L
C
D
t
i
m
e
d
b
a
c
k
l
i
g
h
t
i
n
g
:
O
F
F
Table C
- FACTORY SETTINGS
/
not to be
allocated: the
same values as
MAIN
settings apply