INSTALLATION
Dra we r Wa rmer ▪ Oper a tor’s M a n ual ▪ M N-46969 ▪ Rev 1 ▪ 5 /2 0
19
How to Install the Drawer Warmer
Before you begin Make sure you have:
▪ An appropriate lifting device, and enough personnel, to safely move and position
the weight of the drawer warmer.
Requirements ▪ The drawer warmer must be installed on a level surface.
▪ The drawer warmer must not be installed in any area where it may be affected by
steam, grease, dripping water, high temperature, or any other severely adverse
conditions.
Electrical
Specifications
Continued on next page
500-2DI V Ph Hz Awg IEC A Breaker (A) kW Plug Configuration Certification
120V
120
1 60 14 — 10.7 15 1.28 NEMA 5-15P
20A-125V plug
208-240V
208
160 14 —5.3 15 9.6
NEMA 6-15P
20A-125V plug
240 1 60 14 — 5.3 15 1.28
230V
230
1 50/60 1.5mm^2 — 5.1 16 1.18
CEE 7/7 | BS-1363 | CH2-16P
Plugs rated 250V
Electrical connections must meet all applicable federal, state,
and local codes.
CEE 7/7 BS-1363 CH2-16P AS/NZS 3112
500-DN
V Ph Hz Awg IEC A Breaker (A) kW Plug Configuration Certification
120V
120 1 50/60 14 — 5.3 15 .64 NEMA 5-15P
20A-125V plug
208-240V
208 1 50/60 14 — 2.7 15 .64
NEMA 6-15P
20A-125V plug
240 1 50/60 14 — 2.7 15 .64
230V
230
1 50/60 1.5mm^2 — 2.6 16 .59
CEE 7/7 | BS-1363 | CH2-16P
Plugs rated 250V
Electrical connections must meet all applicable federal, state,
and local codes.
CEE 7/7 BS-1363 CH2-16P AS/NZS 3112