OPERATION
Dra we r Wa rmer Oper a tors M a n ual M N-46969 Rev 1 5 /2 0
29
How to Calibrate the Temperature Sensor
Before you begin The oven must be connected to electrical power and on.
Make sure you have a multimeter with a thermocouple attachment.
Make sure you have read the topic How to Display the Set and Actual Temperature.
Procedure To calibrate the temperature sensor, do the following.
Step Action
1. Clean the temperature sensor with a damp cloth.
2. Suspend a multimeter thermocouple in the center of the drawer. Do not
allow the
thermocouple to touch any surface.
Close the drawer, and do not open it until calibration is complete.
3. Press the up or down arrows a to set the temperature to 140°F (60°C).
Continued on next page