OPERATION
Dra wer Wa rmer Oper a tors M a n ual M N-46969 Rev 1 5/ 2 0
30
Continued from previous page
4. Allow the drawer warmer to heat for 60 minutes.
Calibrate the offset number. Subtract the smaller value from the larger
value. This is the offset. If the value measured by the multimeter was the
larger value, the offset will positive “+”. If the value measured by the
multimeter was the smaller value, the offset will be negative “–”.
5. If the multimeter temperature and the Actual temperature don’t match,
press and hold the Up and down arrow buttons
b for eight (8) seconds. The
control will display the previous calibration offset value or 0.
6. Press the Up or down arrows c to set the appropriate offset value.
Example: If the multimeter temperature is 145°F, and the Actual
temperature is 140
°F, set the offset to +5 from the original offset to bring
the Actual temperature to 145
°F.
Continued on next page