MN-29756 (Rev. 5) 12/17 • TH-SK Series Cook, Hold, Smoke • 
Cleaning and Preventative Maintenance
Daily
Perform daily oven cleaning as stated in this guide.
Clean front drip tray as recommended in this guide.
Monthly
Inspect the door gasket for signs of cracking, deformation, or damage and replace asneeded.
Inspect the door window gasket for proper seal.
Inspect the cavity door vent slides for proper operation.
Inspect the side racks, shelves and shelf supports for damage and replace as needed.
Calibrate removable product probe (if applicable).
Clean the cooling fan intake area and exhaust vents.
Visually inspect the smoke element (if applicable). If any visual signs of deformation, cracks or breaks are seen, remove the oven
from service and contact a factory authorized service technician for service.
Every 12 months (Inspection by a factory authorized technician)
Open the control area and inspect and tighten all electrical connections.
Inspect all electrical components.
Inspect the smoke element and smoke element wiring (if applicable).
Visually inspect the smoke element (if applicable). If any visual signs of deformation, cracks or breaks are seen, remove the oven
from service and contact a factory authorized service technician for service.
Conrm proper current draw of heating elements.
Test heating elements for electrical short to ground. Replace/repair as needed.
Inspect the condition of the plug and cord and replace if damaged.
Tighten the cord connection inside the appliance control area.
Test/replace independent indicator lights (where applicable).
Replace the control cooling fans (if applicable).
Check the site voltage.
Set the voltage switch (where applicable).
Inspect and test the product probe and product probe receptacle.
Inspect and test the control and control functions.
Replace the control knobs.
Visually inspect the cavity for structural integrity.
Replace the door gasket.
Visually inspect any door handles and hinges. Replace/repair as needed.
Remove any loose handle and hinge screws. Apply Loctite
®
and then properly secure the screws.
Inspect the perimeter bumper. Repair/replace as needed.
Inspect the casters. Repair/replace as needed.
Perform cavity temperature calibration per manufacturer’s recommended calibrationprocedures.