Operation and Care Manual #861
4
COOKING OVEN CHARACTERISTICS
The oven is equipped with a special, high-heat-density,
heating cable. Through the HALO HEAT concept, the
heating cable is mounted against the walls of the cooking
cavity to provide an evenly applied, thermostatically
controlled, heat source. The design and operational
characteristics of the oven eliminates the need for a
moisture pan or a heat circulating fan. Through even heat
application, the quality of a food product is maintained for
many hours.
THERMOSTAT/PILOT LIGHT SEQUENCE
Whenever the thermostat is turned ON, the pilot light
will indicate the power
ON/OFF condition of the heating
cable, and consequently, the cycling of the cabinet as it
maintains the dialed cavity temperature. If the pilot light
does not illuminate after normal start-up, the main power
source, thermostat, and/or pilot light must be checked. If
the warming cabinet does not hold the temperature as
dialed, the calibration of the thermostat must be checked. If
the warming cabinet fails to heat or heats continuously with
the thermostat
OFF, the thermostat must be initially
checked for proper operation. If these items are checked
and found to be in order, a continuity and resistance check
of the heating cable should be made.
SEE CIRCUIT
DIAGRAM.
THERMOSTAT CALIBRATION
The thermostat is precision calibrated at the factory.
Normally, no adjustment or recalibration is necessary unless
the thermostat has been mishandled in transit, changed or
abused while in service. A thermostat with a sensing bulb
operates on hydraulic pressure, consequently, any bending
of the bulb results in a change in its volume, and alters the
accuracy of the thermostat calibration.
A thermostat should be checked or recalibrated by
placing a quality, thermal indicator at the center of an empty
holding cavity.
DO NOT CALIBRATE WITH ANY FOOD
PRODUCT IN THE CABINET.
The thermostat should be
set, and should be allowed to stabilize at that setting for a
minimum of one hour. Following temperature stabilization,
the center of the thermal swing of the air temperature within
the cabinet should approximately coincide with the
thermostat setting.
If calibration is necessary, the calibration screw should
be adjusted with great care. The calibration screw of the
thermostat is located in the thermostat dial shaft. With the
shaft held stationary, a minute, clockwise motion of the
calibration screw appreciably lowers the thermostat setting.
A reverse, or counter-clockwise motion appreciably raises
the thermostat setting. After achieving the desired cycling of
the thermostat, the calibration screw must be sealed. Place
a few drops of enamel sealant directly on the calibration
screw.
(Red nail polish or equivalent is acceptable.)
SPECIFICATIONS
AA
AA
AA
AA
AA
25-3/8"(645-mm)
28-1/4"(718-mm)
30-7/8"(784-mm)
53-3/4"(1365-mm)
2-5/8"
(67-mm)
24-1/4"(616-mm)
ALTO-SHAAM
ELECTRICAL CONNECTION
6"(152-mm)
FOR CASTERS
CH-75/DM
C
L
ELECTRICAL
CONNECTION
3-1/8"(79-mm)
FROM TOP
27-3/8"(695-mm)
100 lb (45 kg) maximum
18 gauge non-magnetic (non-corrosive) stainless steel
two (2) non-magnetic stainless steel side racks
with shelf rungs spaced at 1-3/8" (35mm) centers
Three (3) non-magnetic stainless steel wire shelves
One (1) stainless steel drip pan
One (1) 40 watt appliance bulb
W x L x H: 21-7/8" x 26-1/2" x 19-3/4"
(556mm x 673mm x 502mm)
FULL-SIZE PANS GASTRONORM 1/1
Ten (10) 12" x 20" x 2-1/2" (530mm x 325mm x 65mm)
Six (6) 12" x 20" x 4" (530mm x 325mm x 100mm)
Four (4) 12" x 20" x 6" (530mm x 325mm x 150mm)
SHEET PANS
Up to five (5)* 18" x 26" x 1" on wire shelves only.
*Additional shelves required.
120/208-240 V.A.C. 60 Hz, 1 ph
3000 Watts (maximum) NO CORD & PLUG
14.8 Amps (maximum)
220 V.A.C. 50 Hz, 1 ph
2400 Watts
BARE END - NO PLUG
10.9 Amps
197 lb (89 kg)
223 lb (101 kg)