Nexto Logger
Nexto Series
NL717
CE117100 Rev. B
8. FSB8
ADAPTATIVE_DATA_RATE: The Data Rate parameter of LoRa communication indicates the bandwidth at which the
message will be sent. The higher the Data Rate, the greater the capacity for sending data, i.e. more data can be sent
in a single message. Conversely, the higher the Data Rate, the less effective the communication over long distances,
significantly decreasing the communication distance. When the ADAPTATIVE_DATA_RATE mode is activated, the
server takes care of choosing the ideal Data Rate for device communication, this adaptation process is time consuming
and can cause a lot of communication instability, with few real gains associated with it. It is recommended to disable
this function, so the device will communicate at the lowest Data Rate, but having a significant gain in communication
distance.
ACT_TYPE: Mode in which the device will be joined on the server. The first join mode, OTAA, allows the device to
exchange access and encryption keys with the server during the join process. In this way the encryption keys are hidden
and secure during the entire process, this is the most secure mode of join. In the second join mode, ABP, the access and
encryption keys are pre-generated and loaded on the device before the join process. This mode offers a faster and easier
join process but is less secure, since the encryption keys can be misappropriated.
Configuration options:
1. OTAA
2. ABP
ABP_KEYS: Receives a structure of type LORA_ABP_CONFIGURATION that must be filled in if the choice of join
mode is of type ABP.
LORA_ABP_CONFIGURATION: Different from the others, which list available options, this is a data structure
that contains the three keys needed for the join of ABP type.
1. ABP_APP_SESSION_KEY: Receives the pointer of a vector that contains the saved key;
2. ABP_NWK_SESSION_KEY: Receives the pointer of a vector that contains the saved key;
3. ABP_DEV_ADDR: Receives the pointer of a vector that contains the saved key.
Figure 12: LORA_ABP_CONFIGURATION
OTAA_KEYS: Receives a structure of type LORA_OTAA_CONFIGURATION that must be filled in if the choice of
join mode is of type OTAA.
LORA_OTAA_CONFIGURATION: Data structure that contains the two keys needed for the join of OTAA type.
1. OTAA_APP_EUI: Receives the pointer of a vector that contains the saved key;
2. OTAA_APP_KEY: Receives the pointer of a vector that contains the saved key.
Figure 13: LORA_OTAA_CONFIGURATION
20

Other manuals for ALTUS Nexto Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ALTUS Nexto Series and is the answer not in the manual?

ALTUS Nexto Series Specifications

General IconGeneral
BrandALTUS
ModelNexto Series
CategoryComputer Hardware
LanguageEnglish

Related product manuals