2 www.amana-hac.com SS-ACVC96
SS-ACVC96 www.amana-hac.com 3
¹ NaturalGasBTU/h
² DOEAFUEbaseduponIsolatedCombusonSystem(ICS)
³ InstallermustsupplyoneortwoPVCpipes:oneforcombusonair(oponal)andonefortheueoutlet(required).
Ventpipemustbeeither2"or3"indiameter,dependinguponfurnaceinput,numberofelbows,lengthofrunandinstallaon(1or2pipes).TheoponalCombusonAirPipeis
dependentoninstallaon/coderequirementsandmustbe2"or3"diameterPVC.
⁴ MinimumCircuitAmpacity=(1.25xCirculatorBlowerAmps)+IDBloweramps.WiresizeshouldbedeterminedinaccordancewithNaonalElectricalCodes.Extensivewireruns
willrequirelargerwiresizes.
⁵ MaximumOvercurrentProteconDevicereferstomaximumrecommendedfuseorcircuitbreakersize.MayusefusesorHACR-typecircuitbreakersofthesamesizeasnoted.
Notes
Allfurnacesaremanufacturedforuseon115VAC,60Hz,single-phaseelectricalsupply.
GasServiceConnecon½"FPT
Important:SizefusesandwiresproperlyandmakeelectricalconneconsinaccordancewiththeNaonalElectricalCodeand/orallexisnglocalcodes.
Forboomreturn:Failuretounfoldangesmayreduceairowbyupto18%.Thiscouldresultinperformanceandnoiseissues.
Forservicingorcleaning,a24"frontclearanceisrequired.Unitconnecons(electrical,ueanddrain)maynecessitategreaterclearancesthantheminimumclearanceslisted
above.Inallcases,accessibilityclearancemusttakeprecedenceoverclearancesfromtheenclosurewhereaccessibilityclearancesaregreater.
ACVC96
0403BNA
ACVC96
0603BNA
ACVC96
0804CNA
ACVC96
1005CNA
ACVC96
1205DNA
Heating Data
HighFireInput¹ 40,000 60,000 80,000 100,000 120,000
HighFireOutput¹ 38,400 57,600 76,800 96,000 115,200
Low-FireSteady-StateInput¹ 28,000 42,000 56,000 70,000 84,000
Low-FireSteady-StateOutput¹ 26,880 40,320 53,760 67,200 80,640
AFUE² 96 96 96 96 96
TemperatureRiseRange(°F) 20-50 35 - 65 25-55 45-75 35 - 65
VentDiameter³ 2"-3" 2"-3" 2"-3" 2"-3" 2"-3"
No.ofBurners 2 3 4 5 6
Circulator Blower
AvailableAC@0.5"ESP 1.5 - 3 1.5 - 3 1.5-4 2-5 2-5
Size(DxW) 10"x8" 11"x8" 11"x10" 11"x10" 11"x11"
Horsepower@1075RPM ½ ½ ¾ 1 1
Speed VSECM VSECM VSECM VSECM VSECM
Electrical Data
Min.CircuitAmpacity⁴ 7.8 7.8 10.6 14.4 14.4
Max.OvercurrentDevice(amps)⁵ 15 15 15 20 20
Shipping Weight (lbs) 116 119 143 145 158
Product Specifications