PHB**C/PHD**C
WARNING
To avoid death, personal injury or property damage, do not use this unit if
any part of the unit has been under water. Immediately call a qualified
service technician to inspect the unit and to replace any part of the
control system.
You have purchased a heat pump package unit. It is approved for an
outdoor installation only and is designed to provide many years of safe and
dependable service with proper installation, use, and maintenance. Take
time to familiarize yourself with the information concerning unit installation,
features, operation, and maintenance contained within this manual. Refer to
the Specification Sheet for the needed clearance around the unit.
Please take the time to fill out your owner’s registration card and mail it
today. This will assist Amana in contacting you should any service or war-
ranty information change in the future. When filling in the registration card,
be sure to include the Model, Manufacturing and Serial Numbers, plus the
installation date. If the registration card cannot be located, please call 1-800-
843-0304 to register the unit.
Your warranty certificate is also supplied with the unit. Read the warranty
carefully and note what is covered. Keep the warranty certificate in a safe
place, so you can find it, if necessary. Before using this manual, check the
serial plate for proper model identification.
Installer - Affix this manual, the Installation Guide, and Specification Sheet
adjacent to the appliance.
Owner - Keep all product literature in a safe place for future reference.
10500211May 1999 (2)
®
Due to policy of continual product improvement, the right is reserved to
change specifications and design without notice.
Heat Pump Package Unit
Users Information Manual
THE INSTALLATION AND SERVICING OF THIS
EQUIPMENT MUST BE PERFORMED BY QUALIFIED,
EXPERIENCED TECHNICIANS ONLY.
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION
®

Other manuals for Amana PHD**C

Question and Answer IconNeed help?

Do you have a question about the Amana PHD**C and is the answer not in the manual?

Summary

General Information

Unit Location

Specifies that the unit is approved for outdoor installation only and requires clearance.

Indoor Humidity

Explains relative humidity, its impact on health, and provides a table of recommended indoor humidity levels.

Thermostat

Details the importance of thermostat quality, placement, and types for optimal unit operation.

Indoor Air Circulating Blower

Advises to keep the blower access door and panel in place for inspection and maintenance.

Compressor Protection Devices

Describes components that protect the compressor from abnormal operating conditions.

Operating Instructions

Routine Maintenance

Covers filter replacement, coil cleaning, and lubrication for blower and fan motors.

Questions and Support

Consumer Information Line

Provides Amana's toll-free number for inquiries about products and services.

Extended Service Plan

Information on purchasing an extended service plan for additional parts and labor coverage.

Summary

General Information

Unit Location

Specifies that the unit is approved for outdoor installation only and requires clearance.

Indoor Humidity

Explains relative humidity, its impact on health, and provides a table of recommended indoor humidity levels.

Thermostat

Details the importance of thermostat quality, placement, and types for optimal unit operation.

Indoor Air Circulating Blower

Advises to keep the blower access door and panel in place for inspection and maintenance.

Compressor Protection Devices

Describes components that protect the compressor from abnormal operating conditions.

Operating Instructions

Routine Maintenance

Covers filter replacement, coil cleaning, and lubrication for blower and fan motors.

Questions and Support

Consumer Information Line

Provides Amana's toll-free number for inquiries about products and services.

Extended Service Plan

Information on purchasing an extended service plan for additional parts and labor coverage.

Overview

This document is the User's Information Manual for the Amana PHBC/PHDC Heat Pump Package Unit, specifically dated May 1999 (2). It provides essential information for the safe and dependable operation, installation, and maintenance of the unit.

Function Description:

The Amana PHBC/PHDC is a heat pump package unit designed for outdoor installation only. Its primary function is to provide heating and cooling for a building, offering year-round climate control. The unit is designed for safe and dependable service, provided it is properly installed, used, and maintained according to the instructions in this manual. It is crucial to register the unit with Amana to ensure proper communication regarding service or warranty information. The unit's warranty certificate is also supplied and should be kept in a safe place for future reference.

Important Technical Specifications:

While specific technical specifications like BTU ratings or power consumption are not detailed in this user manual, it emphasizes several operational parameters. The unit is approved for outdoor installation only. It is not designed to provide mechanical cooling at outdoor temperatures below 50°F; if low ambient cooling is required, a qualified servicer should be consulted. The compressor includes protection devices designed to safeguard it against abnormal operating conditions, which do not affect the indoor blower's operation. These devices can cause a delay (up to five minutes) before the compressor starts. The manual also provides a table of recommended maximum indoor relative humidity levels based on outdoor temperatures, ranging from 35% RH at +20°F outdoor temperature to 15% RH at -20°F outdoor temperature. This highlights the unit's role in managing indoor air quality and preventing condensation issues.

Usage Features:

The unit's operation is controlled by a room thermostat, which must be of good quality and correctly installed to ensure accurate temperature sensing. The thermostat should be located away from hot or cold drafts or spots on walls. Most thermostats will control both heating and cooling functions and feature a Fan Switch with "Auto" and "ON" settings. In "Auto" mode, the circulating air blower cycles on and off with the heating/cooling demand, while in "ON" mode, it runs constantly. Some thermostats offer automatic switching between heating and cooling, or night setback capabilities to lower temperatures during unoccupied periods. The manual outlines the basic steps for operation: turning on the electrical power, setting the thermostat selector switch to COOL or HEAT (or AUTO if available), and setting the desired temperature. A crucial warning states that the unit should not be used if any part has been under water, and a qualified service technician must be called immediately in such an event. The manual also warns against using the unit as a "construction heater" during building finishing phases, as this can lead to premature failure due to low return air temperatures and exposure to dirty atmospheres.

Maintenance Features:

Routine maintenance is essential for the unit's efficiency and longevity. The manual stresses the importance of never operating the unit without a filter installed, as dust and lint can build up, leading to efficiency loss, equipment damage, and potential fire. While a return air filter is not supplied with the unit, a means of filtering return air must exist, typically located in the return air duct(s). Filter inspection should occur at least every two months, or more frequently depending on local conditions and usage. Dirty throwaway filters must be discarded and replaced, while dirty permanent filters should be washed, thoroughly dried, and sprayed with a filter adhesive before reinstallation. Air flow arrows on the filter must point in the proper direction when installing or reinstalling.

For cleaning the outside coil, it must be inspected annually and cleaned as frequently as necessary to keep finned areas free of lint, hair, and debris. This task, however, is designated for a qualified servicer only, and electrical power must be disconnected before cleaning to prevent electrical shock. The indoor air circulating blower motor and the outdoor coil fan motor are permanently lubricated and do not require additional oiling. Similarly, the compressor motor is hermetically sealed and does not require additional oiling. The manual strongly advises that installation and servicing of this equipment must be performed by qualified, experienced technicians only, emphasizing safety precautions and the potential for personal injury or death if performed by unqualified persons. It also provides a consumer information line (1-800-843-0304) for general questions and information on Amana products, and mentions an extended service plan available through participating dealers for additional parts and labor coverage.

Amana PHD**C Specifications

General IconGeneral
BrandAmana
ModelPHD**C