15Lockit+ Users manual |
9.2 ACN Settings
Monitor and manage all Lockits within the selected ACN channel.
“Your Lockit+”
Start C-Jam master
Select ACN channel
Rename unit
ACN Radar
Check status of connected devices (online/oine)
Grid view and list view of ACN devices
- Online / oine
- Rename units
- Battery status
- Timecode aberration
Project tune devices
Note: If you want to re-calibrate your Lockit Setup after some years of operation,
you can perform a Project Tune (former feature of the discontinued ACC controller).
All Lockits within the selected ACN Channel will be tuned simultaneously.
The process will take approx. 2 minutes during which the devices will rapidly blink
red and green.
Tune value will be overwritten by the factory value on a factory reset.
Attention: NEVER initiate a Project Tune during a shoot. There will be a hard reset
of the sync pulse when the process is nished. This will potentially bring cameras
in operation out of clock and compromise active recordings.