How Your EASYHEAT Works
34
Precision Induction Heating
A
MBRELL
®
Doc#
801
-
9526
-
00.doc
2
2
.
.
5
5
B
B
e
e
f
f
o
o
r
r
e
e
Y
Y
o
o
u
u
C
C
a
a
l
l
l
l
S
S
e
e
r
r
v
v
i
i
c
c
e
e
If your heating results are inconsistent or have fallen below an earlier level, please refer
to this section first to ensure that all electrical connections are secure.
ensure tap wiring and internal settings agree
if Ready turns off while heating, see §3.5
remove all power and water from your system; wait 5 minutes
use Philips screwdriver to remove cover screws
examine all connections in boxed areas; ensure secure connections
check RF power cable connection (arrow)
Tighten RF cable
connection
Tighten all screw
terminals
Check, secure all
connectors
Check, secure all
screw terminals
Check, secure all
circuit connectors
Ensure 50lbin
torque, 2 hex head
screws

Related product manuals