89
Note:
For the following example, the programming protocol is assumed to be Standard
Location Protocol, ELT with C/S type approval number and Serial Number (Long
Message.) Other protocols are possible and the exact read-outs of the Computer Test
Set will vary. Refer to the applicable operation manual included with the Computer
Test Set or contact AMERI-KING for assistance.
To verify the digital message, perform the following steps:
Setup
Use provided cable to connect the ELT (RJ-12 port) to the PC (USB port)
3.4.8.1 ELT ID Reading
Step1: Double-Click AK451 Icon to run the program. The programming window
appears as below:
Note: If you don’t see the window above, you may try the other USB port.
Step 2: Set the ELT main switch to “ARM” position.
Step 3: Verify the LED ‘ON’ light illuminates for 4 seconds.
Step 4: At the “:>_” prompt, type: “Password” command then press “Enter” to go to
main menu. Must type this command within next 20 seconds after the
command prompt appears.
Note: If there is no programming command input in this time window, the ELT will
enter the Self-Test mode, and you cannot program the ELT. In this case, set the
ELT switch to “OFF” position and start again from step 2.2.

Table of Contents