Support 16
Type T Pump Operation Manual
4 Remove the check valve spacer, spring, valve poppet, and check valve o-ring.
5 Inspect the check valve o-ring, and replace it if necessary. Then re-install the o-ring, valve poppet, spring, and check valve spacer.
6 Slowly pump two and one-half strokes, positioning the pump lever at approximately 45 degrees, halfway through its stroke.
7 Allow system uid to ow out of the low pressure check valve, ushing entrapped air.
8 Examine the port for air bubbles which may adhere to the threads or parts.
Note: If air bubbles are present, repeat steps 2 through 5 until no more air bubbles appear.
9 Install the check valve plug and o-ring and tighten partially.
10 If installing the low pressure/high volume check valve plug... Tighten the check valve plug.
The procedure for the low-pressure/high volume side is now complete.
11 If installing the high pressure/low volume check valve plug... Use slight pressure on the hand lever to push system uid past the high
pressure/low volume check valve plug to ensure complete purging of the valve port.
12
Tighten the high pressure/low volume check valve plug.
13 Operate the pump handle until pumping becomes dicult.
14 Raise the pump handle to the top of its stoke.
15 Push in the valve rod selector to the high pressure/low volume position.
16 Resume pumping to verify the pump is operating properly.
Check Valve Spacer
Spring
Valve Poppet
Check Valve O-ring