Pump Does Not Hold Pressure
 X
Problem:  The pump operates but the pressure declines beyond normal adiabatic eects. 
 X
Solution:  One of two o-rings may be leaking. As the pressure drops, observe the hand lever. If the hand lever rises, the discharge check valve is leaking and 
its o-ring should be replaced.
 X
To Replace the Discharge Check Valve O-ring
1  Remove the plug and o-Ring from the front of the pump body.
2  Use a screwdriver to loosen and remove the retaining plug. then remove the guide rod, spring, valve poppet and check valve o-ring.
 
3  Inspect the check valve o-ring, and replace it if necessary. Then re-install the o-ring, valve poppet, spring, and guide rod.
4  Thread in the retaining plug until it is tightly seated. Then back o 3 ½ turns to provide sucient travel for the valve poppet.
5  Install the check valve plug and o-ring.
Guide Rod