Model 415
Operation Manual
Docume
nt No. 740084
Revision N
7
2. INPUT POWER, DETAIL - The M-415 can have 1 of 3 operating ranges:
Voltage Phase - Freq.
Max Input Current
Required
Transformer Type Model 415
Main Circuit Breaker
200 VAC 3 - 50/60 Hz 50 amperes Service
Universal 60 Ampere-600 VAC
240 VAC 3 - 50/60 Hz 45 amperes Service
60 Ampere-600 VAC
400 VAC 3 - 50/60 Hz 25 amperes Service
60 Ampere-600 VAC
440 VAC 3 - 50/60 Hz 25 amperes Service
60 Ampere-600 VAC
480 VAC 3 - 50/60 Hz 20 amperes Service
60 Ampere-600 VAC
575 VAC 3 - 50/60 Hz 20 amperes Service
60 Ampere-600 VAC
FOR POWER SUPPLIES MADE BEFORE JANUARY 1999
200 VAC 3 - 50/60 Hz 60 amperes Service
International 60 Ampere-415 VAC
220 VAC 3 - 50/60 Hz 60 amperes Service
60 Ampere-415 VAC
380 VAC 3 - 50/60 Hz 40 amperes Service
60 Ampere-415 VAC
415 VAC 3 - 50/60 Hz 40 amperes Service
60 Ampere-415 VAC
FOR POWER SUPPLIES MADE BEFORE JANUARY 1999
230 VAC 3 - 50/60 Hz 50 amperes Service
Domestic USA 50 Ampere-600 VAC
240 VAC 3 - 50/60 Hz 40 amperes Service
50 Ampere-600 VAC
440 VAC 3 - 50/60 Hz 40 amperes Service
50 Ampere-600 VAC
480 VAC 3 - 50/60 Hz 40 amperes Service
50 Ampere-600 VAC
3. OUTPUT POWER - Straight polarity, constant current DC regulation intended for GTAW
welding only.
Minimum current Output all cases .................... = 5 Amperes DC
Maximum current Output ................................. = 400 Amperes DC continuous or peak pulse
4. CIRCUIT BREAKER – Also used as ON/OFF switch, is a 60 Amp 3 phase Auto-Trip, with
electrical Emergency Stop function available on the Power Supply, Operators Pendant and
from an Optional External Hard Wire Command.
5. POWER CABLE -25 foot (7.6 m) Neoprene jacketed harmonized CE approved 4 conductor 8
AWG (10mm²) cordage, rated voltage: 500V.
6. STANDARDS - The M-415 is designed and maintained to meet all applicable IEC and ISO
standards as well as all applicable EC Directives.
7. RATED CONDITIONS - The system will meet or exceed the functional ranges and
tolerances stated, provided that the following conditions exist:
1. Input Voltage does not deviate greater than +/- 10% from normal voltage.
2. Ambient operating temperature range is between 0 degree C (32° F) and 40° C (105° F)
3. Arc Voltage at the power supply terminals is equal to or less than 30 volts.
4. All electrical performance is based on maximum weld head distance of 200 feet (61 m)
from the M-415
2.1 PHYSICAL CONSTRUCTION
1. Cabinet material - aluminum and steel
2. Dimensions (basic Power Supply):
Height: 39 inches (990.6 mm)
Width: 26 inches (660.4 mm)
Depth: 36 inches (914.4 mm)
3. Weight: Less than 700 lb. (317.5 kg) depending on configuration