Page 3
2.1 FACP Configuration Examples
TYPICAL FRONT DOOR LAYOUT FOR A FULLY POPULATED PANEL
NOTE: PANEL LAYOUT MAY VARY DEPENDING ON CLIENT CONFIGURATION
X- MAF (341-0015) CONSISTS OF:
1- CONTROL PANEL BOARD (302-6906)
1- MAIN BOARD (BRD85MBA"X"-A)
1- CPU (BRD85CPU"X"-D)
X-SLAVE CPU (302-6692)
MAIN CONTROL BOARD (BRD85MBA)
20 WAY
10 WAY
FRONT PANEL CONTROL (302-6906)
CN3
CN21
CN20
TH1
CN8
CN1
CN6
D13
D14
CN3
C12
BZ1
CN5
CN2
CN7
CN11
CH16
CH15
CH6 CH8
CH2
CH1
CN16
CN14
CN18
R17
TP3
RN17
RN20
CN4
CN10
CN15
CN13
CN17
c
ba
4 3 2
BRIG ADE I/F
FRON T PA NELEXPAN SION LED S
EXPAN SION PANE L
MODE M
27V IN
PRIN TER
PSU MON ITOR
LOOP COM MS
1
+
3 WAY
CN1
CN2
1
SLAVE CPU
(302-6692)
CH8
CN1
CN2
1
CH8
CN1
CN2
1
16 WAY
SLAVE CPU
(302-6692)
SLAVE CPU
(302-6692)
U15
CN2
a b
c
U11
U10
U14
U13
CPU BOARD
(BRD85CPU)
PRINTER PSU (302-7130)
C/W CAB2153
26 WAY
CN3
10 WAY
+ -+ -
+ -
AUXILIARY
+ BAT -+ IN -DBA/MCP
DOOR SW
BELL2BELL1
FAULTVALVE MON
BATT FAIL
NO C NC
NO C NC
NO C NC
NO C NC
NO C NC+ - + - NO C NC
+ -
+ -
ALARM IS OLATE
C
SGD II
WARN SYSAUX POW ER O/P
TB10
CN3
TB4
CN2
CN1
TB6
TB5
CN6
TB3
CN5
TB2
BRIGADE
O/P TERM
BOARD
(302-6732)
EARTH
STUD
MAINS
SWITCH
POWER
SUPPLY
UNIT
CABINET BACKPAN VIEW
SHOWING MODULES FITTED
TO THE BACKPAN
AND WIRING DETAILS
TO BATTERIES
TB1
TB2
CN2
CN1
TB3
CTS
RTS
RXD
TXD
COM
D ABCS-+ D ABCS-+
COMMS OUTCOMMS IN
OUT
CTS
RTS
RXD
TXD
COM
SCRN
TRX-
TRX+
0V
+27V
TB3
CN1
TB2
TB1
CN3
OPTIONAL NETWORKING BOARDS
302-7240 NETWORK INTERFACE CARD
302-7250 CONTROLLER INTERFACE CARD.
NOTE: POSITION MAY VARY AS SHOWN
AND IS FOR INDICATION ONLY.
302-7240
302-7250
X- PRINTER
(OEM1447)
C/W MOUNTING
PLATE.
(KIT = 159-0093)
GENERAL INDICATOR, OR
DANGER
240V
FAN CONTROL OR
AGENT RELEASE
CN1CN3
2 LOOP TERMINATION BOARD
(302-7350) OR
16Z CONVENTIONAL BOARD
(302-671B)
L2+ L1-
B
L2+ L1-
A EXT
+35V
EXT
+35V
L2+ L1-
B
L2+ L1-
A EXT
+35V
EXT
+35V
SERIAL RELAY
BRD (302-7320) OR
AGENT TERM BRD
(BRD25ATB) OR
FAN TERM
BRD (BRD25FTB)
POWER
CN4
CN2
TX1
POWER
ZD7
CN2
CN1
CN3
MOUNTED ON CONVENTIONAL
OR LOOP TERMINATION BRD
L(AC) N(AC)
-V -V +V +V
(AC)
ACTIVE
NEUTRAL
GROUND
-VE
+VE
Figure 2: Typical Example of an SP2 Layout
FRONT DOOR AND FRONT INNER DOOR REAR VIEW SHOWING
INSTALLED BOARDS ON FRONT INNER DOOR AND WIRING DETAILS
+ -+ -
+ -
AUXILIARY
+ BAT -+ IN -DBA/MCP
DOOR SW
BELL2BELL1
FAULTVALVE MON
BATT FAIL
NO C NC
NO C NC
NO C NC
NO C NC
NO C NC+ - + - NO C NC
+ -
+ -
ALARM ISOLATE
C
SGD II
WARN SYSAUX POWER O/P
TB10
CN3
TB4
CN2
CN1
TB6
TB5
CN6
TB3
CN5
TB2
CABINET BACKPAN VIEW
SHOWING MODULES FITTED TO THE BACKPAN
AND WIRING DETAILS
BRIGADE
PSU MON.
BOARD
MAIN CONTROL BOARD
20 WAY
10 WAY
FRONT PANEL CONTROL
TO BATTERIES
2 LOOP TERMINATION BOARD
OR
16Z CONVENTIONAL BOARD
CN8
CN1
CN6
CN5
CN7
CH15
CH2
CN10
BRIGADE I/F
PRINTER
PSU MONITOR
BLANK
3 WAY
3 WAY
SLAVE CPU 4
20 WAY
EARTH
STUD
302-6880 EXPANSION BOARD
TB1
TB2
CN2
CN1
TB3
CTS
RTS
RXD
TXD
COM
D ABCS-+ D ABCS-+
COMMS OUTCOMMS IN
OUT
CTS
RTS
RXD
TXD
COM
SCRN
TRX-
TRX+
0V
+27V
TB3
CN1
TB2
TB1
CN3
OPTIONAL NETWORKING BOARDS
NETWORK INTERFACE CARD
CONTROLLER INTERFACE CARD.
NOTE: POSITION MAY VARY AS SHOWN
AND IS FOR INDICATION ONLY.
16 WAY
NETWORK
I/F CARD
SLAVE CPU 3
SLAVE CPU 2
SLAVE CPU
6
NOTE: WIRING MAY VARY DUE TO
CLIENT PANEL CONFIGURATION
CH15
CONTROLLER
I/F CARD
CPU BOARD
SLAVE CPU
7
SLAVE CPU
8
MAINS
INPUT
16Z CONVENTIONAL BOARD
CABINET (291-0076)
L(AC) N(AC)
-V -V +V +V
(AC)
POWER
SUPPLY
UNIT
ACTIVE
NEUTRAL
GROUND
-VE
+VE
ANCILLARIES or
HOUSING BLANKS
AGENT RELEASE
MODULE OR
FIRE FAN CONTROL
MODULE
CN1CN3
AGENT TERM
BRD OR
FAN TERM
BRD
ZD7
CN2
RJ45/8 PIN
RJ45/8 PIN
MAINS
SWITCH
DAN GER
240 V
GENERAL
INDICATOR
CARD
X- PRINTER
(OEM1447)
C/W MOUNTING
PLATE.
(KIT = 159-0093)
BLANK
SLAVE CPU
5
Figure 3: Typical Example of an SP8 Layout