15
16
Accuracy: ± (1.0 % rdg + 4 dgts) on 200 to 2 M
ranges: ± (3.0 % rdg + 5 dgts) on 20 M range
± {5.0 % (rdg -10 dgt) + 20 dgt} on 2000 M range
CONTINUITY
Audible indication: Less than 25
DIODE TEST
Test current: 1.2 mA (approximate)
Accuracy: ±(1.5 % rdg + 3 dgts)
Open circuit volts: 3.0 dc typical
LOGIC TEST
Thresholds Logic 1 (Hi): 2.8 V ± 0.8 V
Thresholds Logic o (Lo): 0.8 V ± 0.5 V
Test voltage: TTL 5 VDC
OVERLOAD PROTECTION
Voltage, Resistance, Diode, Continuity, Logic:
1000 VDC or 750 VAC rms
Current: 2 A / 1000 V fast blow ceramic fuse 6.3 × 32 mm
mA JACK: Input warning detects wrong switch / input jack
configuration
AUXILIARY FEATURES
DATA HOLD: Freeze the latest reading on the display.
RANGE: Execute manual range mode.
AUTO Power off: After auto power off, press (RANGE) button
to restart the meter, and the last reading of measurement
will be returned to the display.
35XP-A Electrical Specications
(at 23°C ± 5°C, < 75 % R.H.)
DC VOLTS
Ranges: 400 mV, 4 V, 40 V, 400 V, 1000 V
Accuracy: ± (0.5 % rdg + 1 dgt)
AC VOLTS (45 Hz to 500 Hz)
Ranges:400 mV, 4 V, 40 V, 400 V, 750 V
Accuracy: ± (1.5 % rdg + 5 dgts) 45 Hz to 100 Hz on 400 mV
range: ± (1.5 % rdg + 5 dgts) on 4 V to 750 V ranges