3
Safety information
The product complies with:
UL/IEC/EN 61010-1, CAN/CSA C22.2 No. 61010-1, Pollution Degree 2, Measurement
CAT III 600 V MAX
IEC/EN 61010-2-033
IEC/EN 61010-2-032
IEC/EN 61010-031 (test leads)
EMC IEC/EN 61326-1
Measurement Category III (CAT III) is applicable to test and measure circuits connected
to the distribution part of the building’s low-voltage MAINS installation. This part of the
installation is expected to have a minimum of two levels of over-current protective devices
between the transformer and possible connecting points.
CENELEC Directives
The instrument conforms to CENELEC Low-voltage directive 2014/35/EU and Electromagnetic
compatibility directive 2014/30/EU.
X�Warnings: Read Before Using
To avoid the possibility of electric shock or personal injury:
Use the Product only as specified in this manual or the protection provided by the
instrument may be compromised.
Avoid working alone so assistance can be rendered.
Test on a known signal source within the rated voltage range of the Product both
before and after use to ensure the Product is in good working conditions.
Do not use the Product around explosive gas, vapor, or in damp or wet environments.
Inspect the Product before use and do not use if it appears damaged. Check for cracks
or missing plastic. Pay particular attention to the insulation around the connectors.
Inspect the test leads before use. Do not use if insulation is damaged or metal is exposed.
Do not use the Product if it operates incorrectly. Protection may be impaired. When in
doubt, have the Product serviced.
Check the test leads for continuity. Replace damaged test leads before using the Product.
Have the Product serviced only by qualified service personnel.
Use extreme caution when working around bare conductors or bus bars. Contact with
the conductor could result in electric shock.
Do not hold the Product beyond the tactile barrier.
Do not apply more than the rated voltage and CAT rating, as marked on the Product,
between the terminals or between any terminal and earth ground.
Remove test leads from the Product before opening the Product case or battery cover.
Never operate the Product with the battery cover removed or the case open.
Use caution when working with voltages above 30 V AC RMS, 42 V AC peak, or 60 V
DC. These voltages pose a shock hazard.
Do not attempt to connect to any circuit carrying voltage that may exceed the maximum
range of the Product.
1. PRECAUTIONS AND SAFETY MEASURES