NetLinx Programming
84
NX-Series Controllers - WebConsole & Programming Guide
Master SEND_COMMANDs
These commands are specific to the Master and not the Controller. These commands are sent to the DPS 0:1:0 (the Master you are
connected to).
A device (<DEV>) must first be defined in the NetLinx programming language with values for the Device: Port: System (<D:P:S>).
Master SEND_COMMANDs
Command Description
CLOCK Set the date and time on the Master. The date and time settings are propagated over the local bus.
Syntax:
SEND_COMMAND <DEV>,"'CLOCK <mm-dd-yyyy> <hh:mm:ss>'"
Variables:
mm-dd-yyyy = Month, day, and year. Month and day have 2 significant digits. Year has 4 significant digits.
hh-mm-ss = Hour, minute, and seconds. Each using only 2 significant digits.
Example:
SEND_COMMAND 0,"'CLOCK 04-12-2005 09:45:31'"
Sets the Master's date to April 12, 2005 with a time of 9:45 am.
G4WC Add G4 Web Control devices to Web control list displayed by the Web server in a browser. The internal G4WC
Send command (to Master 0:1:0) has been revised to add G4 Web Control devices to Web control list displayed
in the browser.
Syntax:
SEND_COMMAND <D:P:S>,"'G4WC "Name/Description",IP Address/URL,IP Port,Enabled'"
Variables:
Name/Description = A string, enclosed in double quotes, that is the description of the G4 Web Control
instance. It is displayed in the browser.
IP Address/URL = A string containing the IP Address of the G4 Web Control server, or a URL to the G4 Web
Control server.
IP Port = A string containing the IP Port of the G4 Web Control Server.
Enabled = 1 or 0. If it is a 1 then the link is displayed. If it is a 0 then the link is disabled.
The combination of Name/Description, IP Address/URL, and IP Port are used to determine each unique
listing.
Example:
SEND_COMMAND 0:1:0,"'G4WC "Bedroom",192.168.1.2,5900,1'"
Adds the BEDROOM control device using the IP Address of 192.168.1.2.
~IGNOREEXTERNAL
CLOCKCOMMANDS
Set the Master so that it cannot have it’s time set by another device which generates a ‘CLOCK’ command.
Syntax:
SEND_COMMAND <D:P:S>,"'~IGNOREEXTERNALCLOCKCOMMANDS'"
Example:
SEND_COMMAND 0:1:0,"'~IGNOREEXTERNALCLOCKCOMMANDS'"