1)
If the range hood or halogen light does not
operate after installation:
2)
The range hood vibrates when the blower is on:
3)
The blower or fan seems weak:
4)
The lights work but the blower is not spinning at
all, is stuck or is rattling.
5)
The hood is not venting out properly:
Check if the range hood has been plugged
in, make sure that all power has been
turned back ON, fused not blown and all
electrical wiring are properly connected.
The range hood might not have been
secured properly on to the ceiling or wall.
Check that the duct sized used is at least
6” or 3-1/4 x 10”. Range hood WILL
NOT function efficiently with insufficient
duct size. For example: 7” duct over 6”
hole and loosely secured.
Check if duct is clogged or if damper unit
(half-circular flapper) is not installed
correctly or opening properly. A tight
mesh on a side wall cap unit might also
cause restriction to the air flow.
The blower might be jammed or
scraping the bottom due to shipping
damage. Please contact us immediately.
Make sure the distance between the
stove top and the bottom of the hood
is within 24” and 30 in distance; with
minimum 30” for gaz stove top.
Reduce the number of elbows and
length of duct work. Check if all joints
are properly connected, sealed, and
taped.
: