PRODUCT MANUAL
46/50ST Below Deck Compact Motor
20
GREEN
In normal operation the green LED illuminates continuously for the rst 5 minutes after
switching the circuit breaker to ON, ashes once every 20 seconds thereafter
and goes o a few seconds after switching the circuit breaker to OFF.
CONTINUOUS
with circuit breaker ON
In normal operation the green LED illuminates continuously for the rst 5 minutes after
switching to the circuit breaker to ON, and ashes once every 20 seconds thereafter.
CONTINUOUS
with circuit breaker OFF
Circuit breaker wired incorrectly; positive (+) cable connections to terminals labelled MOTOR
and BATTERY have been inverted.
FLASHING
In normal operation, 5 minutes after switching the circuit breaker to ON the green LED will
switch from continuous illumination to ashing once every 20 seconds.
NOT ILLUMINATED
circuit breaker ON
Circuit breaker wired incorrectly; positive (+) cable connections to terminals labelled MOTOR
and BATTERY have been inverted.
NOT ILLUMINATED
circuit breaker OFF
In normal operation the green LED will go o a few seconds after switching the circuit
breaker to OFF.
RED
The red LED will illuminate if a fault is detected. If a status code is available
it will be indicated by the ashing yellow LED.
NOT ILLUMINATED In normal operation the red LED will not be illuminated.
FLASHING 4 times, then yellow
LED starts ashing
Check Yellow LED status codes below.
FLASHING
yellow LED not ashing
The circuit breaker can not be tripped by signal from PCB. Thermal sensor wires
disconnected, or incorrect connection of positive (+) cables between motor, circuit breaker
and battery.
FLASHING 4 times, then green
and yellow LED start ashing
MINUS wire from circuit breaker to negative (-) battery terminal not connected,
or incorrect/faulty connections to the PCB terminals.
YELLOW
The yellow LED signals a status code by emitting a sequence of ashes once
every 20 seconds.
3 ashes
High system voltage detected when power supply rst connected. Exceeds pre-set limit for
power up; check battery and any battery charging devices.
4 ashes
High current draw detected when power supply rst connected. Exceeds pre-set limit for
power up; may indicate motor failure or incorrect wiring.
5 ashes
Extremely low system voltage detected; check battery, charging devices and electrical
installation.
6 ashes Low system voltage detected; check battery, charging devices and electrical installation.
7 ashes Continuous low current consumption (≥ 15 minutes), check electric installation.
8 ashes Continuous low current consumption (≥ 8 minutes), check electric installation.
9 ashes
High system voltage detected during operation; check battery and any battery charging
devices.
10 ashes Constant high system voltage detected; check battery and any battery charging devices.
11 ashes Status code not assigned.
12 ashes Status code not assigned.
13 ashes Motor overheated above 70°C (158˚F), or damaged thermal sensor wiring.
14 ashes
Circuit breaker wired incorrectly; positive (+) cable connections to terminals labelled MOTOR
and BATTERY on the circuit breaker have been inverted.
LED Status Codes / Diagnostics

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Andersen Compact Motor 46ST and is the answer not in the manual?

Andersen Compact Motor 46ST Specifications

General IconGeneral
BrandAndersen
ModelCompact Motor 46ST
CategoryWinches
LanguageEnglish

Related product manuals