Aneng M118A - AC;DC Current Measurement; NCV Measurement; Automatic Shutdown Function

Aneng M118A
8 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
residual
reading,
the
distributed
capacitance
of
this
digital
meter
pen,
the
bit
accurate
reading
can
subtract
this
value
after
measurement.
3.
A
LCD
will
show
some
values
and
instability
when
measuring
serious
leakage
or
breakdown
capacitance
at
large
capacitance
files;
when
measuring
large
capacitance,
the
reading
takes
a
few
seconds
to
stabilize,
which
is
normal
when
measuring
large
capacitance.
4.
Unit
1
F=1000
mF
lmFF=1000
uF
uF=1000nF
nF=1000
pF
5-5,
Current
Test
Function
(DC/AC
A)
1.Press
the
power
key
for
more
than
2
seconds
to
turn
on
the
meter.
The
boot
is
shown
as
automatic
scan
AUTO".
2.
Insert
black
watch
pen
into
"COM"
jack,
red
watch
pen
insert
"10
A"
jack,
test
watch
pen
reliable
contact
test
point.
3.
Input
current
greater
than
20
mA
between
the
input
port
"COM"
and
"10
A",
the
meter
will
display
the
current
value
with
large
de-component
on
the
LCD
according
to
the
magnitude
of
the
AC
/
DC
component.
Note:
1,
Before
the
instrument
is
connected
in
series
to
the
circuit
to
be
tested,
the
power
in
the
circuit
should
be
turned
off
first;
2,
Maximum
input
current
is
10
A(
depending
on
the
red
meter
pen
insertion
position),
too
much
current
will
burn
out
the
internal
fuse,
be
careful,
each
measurement
time
must
not
be
more
than
10
seconds,
too
much
current
or
too
long
measurement
time
will
make
the
instrument
circuit
heating,
or
even
damage
the
instrument;
3.
Do
not
connect
the
meter
pen
test
pin
parallel
to
any
circuit
when
the
red
meter
pen
is
inserted
in
the
"10
A"
port,
this
will
damage
the
fuse
and
meter.
4.
After
all
the
measurement
operations
are
completed,
the
power
supply
should
be
turned
off
first
and
then
the
connection
between
the
meter
pen
and
the
measured
circuit
should
be
disconnected.
5.
No
more
than
36V
DC
or
25V
AC
voltage
is
entered
between
port
10
and
port
COM".
5-6,
NCV
measurements
1.
Press
the
power
key
for
more
than
2
seconds
to
turn
on
the
meter.
Press
‘NCV’
key
to
enter
EF
measurement,Keep
pressing
the
key
.
2.
Instrument
has
the
NCV
test
induction
end,
the
induction
end
is
close
to
the
AC
voltage
side,
according
to
the
signal
intensity,
the
buzzer
will
make
a
continuous
sound
of
different
frequencies,
at
the
same
time,
the
LCD
will
still
display
different
segments
according
to
the
signal
strength,
VI.
Automatic
Switching
Machine
The
instrument
has
the
function
of
automatic
shutdown,
when
the
instrument
stops
using
for
15
minutes,
the
instrument
will
automatically
power
off
into
the
dormant
state;
to
restart
the
power
supply,
hold
down
the
power
key
more
than
2
seconds,
wake
up
the
instrument
into
the
automatic
scanning
measurement
state,
the
LCD
shows
“AUTO"."
If
you
want
to
cancel
the

Related product manuals