AIRLESS UNITS
GB
This ANEST-IWATA Airless Unit complies to ATEX regulations 94/9/EC.
Protection level: II 2 GX Suitable for use in Zones 1 and 2.
X marking:
Any static electricity discharge from the pump is to be diverted to the ground through
the grounding wire which is included in this product.
Instruction Use and Maintenance Manual
ME0004ENRev.15
ALS 423 TX
ALS 333 C
ALS 433 C
ALS 433 TX
ALS 453 C

Questions and Answers

  • M
    Mr. Anthony MaldonadoAug 9, 2025
    Why does the spray-fan size keep changing on my Anest Iwata Paint Sprayer?
    • A
      alexandramurphyAug 9, 2025
      If the spray-fan size keeps changing on your Anest Iwata Paint Sprayer, it could be due to: * Worn out lip seals. Try adjusting them; if they're too worn, replace them. * Damaged or dirty valves or balls. Disassemble and clean them; replace if necessary. * Worn out inner or outer valves inside the air motor. Replace the valves. * A worn out gun nozzle. Replace the nozzle. * Dirty paint filters. Clean or replace them.
  • S
    Scott TannerAug 13, 2025
    What to do if my Anest Iwata ALS 423 TX Paint Sprayer pump does not stop?
    • V
      Victoria BurkeAug 14, 2025
      If the Anest Iwata Paint Sprayer pump doesn't stop, several issues could be the cause: * Air might be trapped in the paint ducts. Ensure the dip tube is correctly connected. If air remains, increase the paint level to fully cover the dip tube filter set and release air from the paint ducts. * The valves (upper or lower) might be damaged or dirty. Clean any solidified paint residues; if they're damaged, replace them. * The lower lip seals may not be tight. Adjust them or replace them if worn out. * Check for any leakage from the paint ducts and fix it. * Ensure the recirculation valve is closed.
  • J
    James NicholsonAug 19, 2025
    Why does air pressure not increase in my Anest Iwata ALS 423 TX Paint Sprayer?
    • C
      Courtney DelacruzAug 19, 2025
      If the air pressure isn't increasing in your Anest Iwata Paint Sprayer, check the following: * Ensure the ball valve is in the correct position. * Open the air regulator if it's closed. If the regulator is damaged, replace it. * If the compressor doesn't supply enough air pressure, replace it with one of greater capacity.
  • D
    Dana HannaAug 25, 2025
    What to do if the paint does not flow out of my Anest Iwata ALS 423 TX?
    • J
      juliabruceAug 25, 2025
      If the paint isn't flowing out of your Anest Iwata Paint Sprayer, consider these possibilities: * The paint filter or paint circuit may be clogged. Check the paint circuit from the pump inlet to the fluid pipe fitting and remove any obstructions. * The nozzle might be clogged. Free the nozzle with a steel pin and clean it with a non-metallic brush soaked in the suitable solvent. * The safety stop may be jammed. Unlock the safety valve.
  • Z
    zmarquezAug 29, 2025
    Why is my Anest Iwata Paint Sprayer pump not working?
    • A
      andreahughesAug 29, 2025
      If your Anest Iwata Paint Sprayer pump isn't working, the issue could be: * The air supply to the pneumatic motor is insufficient. Replace the motor if it's spoilt or clogged. * There's a technical problem with the equipment. If the motor is running properly, follow the instructions provided in point 2 (a - b). * If the motor is not running properly, disassemble the cylinder and inspect it. In case of special anomalies, ship it to our Customer Care Technical Service.
  • N
    Nicole AlexanderSep 3, 2025
    What causes the air manometer to show pressure when the air regulator is closed on my Anest Iwata Paint Sprayer?
    • B
      Bryan DavisSep 3, 2025
      If the air manometer on your Anest Iwata Paint Sprayer indicates pressure even when the air regulator is closed, the air regulator is damaged and needs to be replaced.

Anest Iwata ALS 423 TX Specifications

General IconGeneral
Nozzle Size1.3 mm
Operating Pressure29 PSI
Cup Capacity600 ml
Fluid Cup Capacity600 ml
TypeHVLP