18
Application Examples
Required Functions
• Loopback State Setting Function
• Jitter Tolerance Function
• Automatic Receiver Test Function
• Link Training Function
USB3.2
Device/Host
MP1900A
Remote Control
Oscilloscope
Test Report
Automation Software
Test signal calibration
USB 3.2 Gen1/2 Receiver Test
Link Training Function
The Link status required for measurement can be configured
automatically using the MX183000A and options.
• The test mode can be transitioned to the Loopback mode
required for evaluating USB3.2 Gen1 and Gen2 devices.
Additionally, the Link Training option (MX183000A-PL022) has an
LTSSM Analysis function for troubleshooting problems the Link status
cannot be configured.
Receiver Jitter Tolerance Test
Jitter Tolerance tests can be automated using the MX183000A-PL001
software to help shorten the design validation time.