Anritsu Site Master S331L User Manual

Anritsu Site Master S331L
284 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
User Guide
Site Masterâ„¢
S331L User Guide
Handheld Cable and Antenna Analyzer Featuring
Classic and Advanced Modes
2 MHz to 4 GHz Cable & Antenna Analyzer
50 MHz to 4 GHz Power Meter
Anritsu Company
490 Jarvis Drive
Morgan Hill, CA 95037-2809
USA
http://www.anritsu.com
Part Number: 10580-00321
Revision: M
Published: July 2017
Copyright 2017 Anritsu Company

Table of Contents

Other manuals for Anritsu Site Master S331L

Question and Answer IconNeed help?

Do you have a question about the Anritsu Site Master S331L and is the answer not in the manual?

Anritsu Site Master S331L Specifications

General IconGeneral
BrandAnritsu
ModelSite Master S331L
CategoryMeasuring Instruments
LanguageEnglish

Summary

Chapter 1 General Information

1-2 Instrument Description

Describes the Site Master S331L's features, display, and input methods.

1-4 Calibration and Annual Verification

Explains calibration requirements and annual verification procedures.

Chapter 2 Instrument Overview

2-2 Turning On the Site Master

Details how to power on the Site Master and its battery life.

Chapter 3 Cable and Antenna Measurements

Line Sweeping

Discusses system performance issues like reflections and insertion losses.

3-4 Line Sweep Measurements

Details three types of line sweeps: Return Loss, Cable Loss, DTF.

Return Loss/VSWR Measurement

Analyzes system interaction by measuring reflected power.

Cable Loss Measurement

Verifies signal attenuation level of the cable.

DTF Measurement

Analyzes impedance mismatches and fault locations in transmission lines.

Distance Resolution

Explains the ability to separate closely spaced discontinuities.

Windowing

Describes windowing techniques for spectral resolution and side lobe reduction.

3-5 Advanced Measurements

Covers advanced measurement techniques for impedance analysis.

Smith Chart

A graphical tool for plotting impedance data versus frequency.

1-Port Phase

Displays the phase of reflection measurements for relative measurements.

Transmission (Ext. Sensor)

Measures cable loss using an external USB power sensor.

3-6 Measurement Setup

Describes how to set up parameters, markers, and limit lines.

Frequency

Details setting start and stop frequencies for measurements.

Distance

Explains how to set start and stop distances for measurements.

Amplitude

Describes setting top and bottom amplitude scale values.

Sweep

Covers setting data points, run/hold, sweep type, and RF immunity.

Limit Lines

Explains using limit lines for visual reference or pass/fail criteria.

Markers

Describes applying markers to active or recalled measurements.

Trace

Allows concurrent viewing of live and stored traces for comparison.

Freq/Dist Menu

Covers frequency and distance settings, including DTF Aid.

Amplitude Menu

Explains amplitude settings like Max/Min Value, Autoscale, and Ref. Impedance.

Calibration Menu

Details calibration options like Start Calibration, Cal Info, and Cal Method.

Marker Menu

Covers marker setup, editing, type selection, and search functions.

Limit Menu

Explains setting limit lines, alarms, and pass/fail messages.

Sweep Menu

Details sweep parameters like data points, run/hold, and RF immunity.

Trace Menu

Provides options for trace display, math, and copying traces.

Chapter 5 Internal Power Meter

5-3 General Measurement Setup

Covers connection, frequency, amplitude, and display settings.

5-4 Power Meter Menus

Presents a map of the Power Meter main and submenus.

5-7 Calibration Menu

Explains the zero sensor calibration procedure.

Chapter 6 High Accuracy Power Meter

6-3 General Measurement Setup

Covers sensor connection, frequency, amplitude, and display settings.

Connection and Offset

Details connecting the USB sensor and setting offset values.

Set the Measurement Frequency

Explains how to set the measurement frequency for the source.

Setting the Amplitude

Describes setting amplitude values and using autoscale.

Setting Upper and Lower Limits

Details how to set measurement limits for forward/reverse values.

Calibration

Describes zeroing the sensor for accurate power measurements.

6-4 MA24105A Inline Power Sensor

Details features and measurements for the MA24105A inline sensor.

In-Line Sensor Setup

Adjusts in-line sensor parameters via the Display main menu.

Modulation

Selects modulation type for refining PEP calculations.

Duty Cycle

Sets duty cycle for averaging in Burst Average Manual mode.

Chapter 7 Calibration

7-2 Calibration Methods

Compares calibration methods: OSL, InstaCal, Transmission, and combined.

7-3 Calibration Procedures

Details OSL and InstaCal calibration procedures.

Chapter 8 File Management

8-4 Save File

Details the process of saving measurement, setup, or screenshot files.

8-5 Recall File

Details recalling saved measurements, setups, or screen shots.

Recall a Measurement

Steps for recalling a saved measurement file.

Chapter 9 System Operations

9-5 Updating the Site Master Firmware

Guides on checking software version and updating firmware.

Chapter 10 Battery Replacement

10-3 Battery Replacement

Step-by-step guide for replacing the Site Master batteries.

Chapter 12 Video Inspection Probe (VIP)

VIP Image Analysis

Guides on analyzing VIP images and interpreting results.

Measurement Menu

Details live view, capture, analyze, and results table functions.