S331L UG PN: 10580-00321 Rev. M 2-1
Chapter 2 — Instrument
Overview
2-1 Introduction
This chapter provides an overview of the Anritsu Site Master S331L.
The intent of this chapter is to acquaint the user with the instrument
and general functionality. For detailed line sweeping information, refer
to Chapter 3 for Advanced mode or Chapter 4 for Classic mode. User
calibration for Cable & Antenna Sweeping is reviewed in Chapter 7.
Power Meter operation is reviewed in Chapter 5 and High Accuracy
External USB Power Meter operation is reviewed in Chapter 6.
2-2 Turning On the Site Master
The Anritsu Site Master S331L is capable of approximately eight hours
of continuous operation from a fully charged battery.
The Site Master can also be operated from a 12 VDC source (which will
also simultaneously charge the battery). This can be achieved with
either the Anritsu AC-DC Adapter or the Automotive Cigarette Lighter
Adapter.
To turn on the Site Master, press the green On/Off button on the front
panel (Figure 2-1 on page 2-3). The Site Master takes approximately
90 seconds to complete initial power up and load the application
software.
Caution
When using the Automotive Cigarette Lighter Adapter,
always verify that the supply is rated for a minimum of
40 Watts @ 12 VDC, and that the socket is clear of any dirt
or debris. If the adapter plug becomes hot to the touch
during operation, discontinue use immediately.