S331L UG PN: 10580-00321 Rev. M 9-23
System Operations 9-9 Preset Menu
9-9 Preset Menu
Key Sequence: Preset (9)
Note
Carefully read the information on screen before performing
any of the functions under the Preset menu. User files that
are deleted cannot be recovered.
Preset:
Preset: Press this key to reset the instrument to the
default conditions.
Preset condition in Cable & Antenna mode: Return
Loss measurement, full frequency range, full amplitude
scale, no calibration, all markers off, and limit line off.
Reset:
Reset: Press this key to display the reset options
shown below. Select the Reset option to apply using
the touchscreen, Up/Down arrow keys or rotary knob.
Carefully read the on screen information before
confirming the reset.
Factory Reset: Press this key to restore the
instrument to the factory default values, including
language, volume, display/audio settings. User
saved files and user created shortcut icons on the
Menu screen are not deleted.
Press the Factory Reset button to initiate the reset,
and power cycle the instrument. Press ESC to
cancel and close.
Delete All User Files: Deletes all user files in Site
Master internal memory including measurements,
setup files, and screen shots. Menu shortcuts,
customized EZ key names, and custom cable types
are not deleted.
To delete all user files, press the Delete All User
Files button and then, press Yes to confirm.
Figure 9-24. Preset Menu (1 of 2)
ese
Update
Firmware
Preset
Reset
Preset