RS1Unit
Radio
receiver
tile
Door
guide
Bottom
rail
Magnet
Alarm
trip
switch
Leavea10mmgapfromthemagnettothedoorguide
AlarmModule
Optional
wiring
connection
tohouse
alarm
system
AlarmStatusLED
Alarmcableplug
andPCBsocket
8 Alarm System - Type AL-12 H/W (optional)
9.1 Function
The AL-12 H/W System is an intruder alarm designed to protect an attempted break in through the garage door. The system
automatically arms when the door is closed and is automatically disarmed whenever the door is opened using the keyfob transmitters
or other access controls. The alarm module is fitted with a 90db siren and alarm status indicator. The alarm module is also equipped
with volt free terminals which provide the option to connect the system direct to the main house alarm. The system uses a sealed
magnetic switch and magnet to trigger the alarm if an attempt is made to force the door open.
8.2 Installation
8.6 Optionalconnectiontomainhousealarmsystem
Green ON - Door is closed and Alarm system is SET
Red ON - Door is open and Alarm system is OFF
Red/GreenFlashing -Doorisopeningorclosingorispartopen
TheANSAAL-12Modularisequippedwithvoltfreenormallyclosedterminalsforoptionaldirectconnectiontothemainhouse
alarmsystem.AbreakinattemptwillcausetheANSAalarmandhousealarmtoactivatesimultaneously.
·
·
·
Fitting the alarm module
Fix the Alarm Module to th left of the RS-1 Control Unit using the plugs and screws provided. Pass the connection lead and plug
through the right hand cable gland entry and route the cable as shown away from the radio receiver tile and connect the plug to the
alarm socket on the RS1 circuit board. NOTE - Do not fit the Alarm module next to the Radio receiver tile.
Operate the motor override and position the door at shoulder height. Fit the alarm magnet to the bottom rail using the self drill/self
tapping screws provided and leave a 10mm gap to the door guide (as shown in figure 16).
Fit the alarm trip switch 'horizontally' as shown to the door guide channel (can be fitted to either guide channel) using the self adhesive
pad supplied. Route the 2 core connection lead neatly and connect to the RS1 control unit as shown in figure 9a. and neatly connect the
wires to the RS1 terminals AL1 and AL2.
Self adhesive fittings & nail clips are provided to secure the alarm module & trip switch cables to the door guide and opening structure.
The unit automatically arms on closure. A ‘break in’ alarm signal is transmitted if the bottom rail is forced open due to interruption of
the magnet and transmitter. Note the alarm automatically resets 15 minutes after it isactivated.
Wait at least 1 minute after the door closes for the system to arm. Use the manual override to raise the door slightly. The alarm should
activate (90 DB sounder). Operate the keyfob to switch off the alarm.
Fit the Alarm Magnet
Fit the Alarm Trip Switch
8.3 Operation
8.4 Testing
8.5 Alarm LED Status Indication
Figure16
Alarmsystemgenerallayoutdiagram
Page7