General safety guidelines and liability information for the safe use of the ViscoQC 300 instrument.
Instructions for safe installation and operation of the ViscoQC 300, emphasizing proper environment and operator training.
Recommendations for maintenance, service, and repair procedures performed by authorized personnel.
Safety measures for handling flammable substances, including ventilation and storage precautions.
Specific safety instructions for handling the ViscoQC 300, including prohibited uses and handling procedures.
Defines the purpose and scope of the ViscoQC 300 as a rotational viscometer for various sample types.
Specifies requirements for instrument installation, including environmental conditions and power supply.
Step-by-step instructions for unpacking and physically installing the ViscoQC 300 instrument.
Procedure for leveling the instrument and performing a zero adjustment for accurate measurements.
Steps to perform the zero adjustment after leveling, ensuring the instrument is ready for operation.
Instructions for connecting the power supply and switching on the ViscoQC 300 instrument.
Guidance on connecting optional components like the Pt100 sensor to the ViscoQC 300.
Detailed steps for connecting and mounting the optional Pt100 temperature sensor.
Details on user account management, logging on/off, and password rules for the ViscoQC 300.
Procedure for calibrating the ViscoQC 300 using a certified reference substance.
Overview of adjustable settings, including spindle correction factors and temperature offsets.
Procedure for setting spindle correction factors (SCF) to adjust measurement results.
Detailed steps and formula for determining the Spindle Correction Factor (SCF).
Step-by-step guide to entering and saving the spindle correction factor in the instrument.
Procedure for setting a temperature offset using an optional Pt100 sensor.
Steps to input and save the temperature offset value for the Pt100 sensor.
Overview of the default measurement methods and how to create or customize methods.
Details on configurable settings for various measurement modes, including specific and general method settings.
Description of the seven available measurement modes on the ViscoQC 300.
Configuration settings that apply across all measurement methods.
Steps for preparing samples and filling sample vessels before measurement.
Safety precautions for handling hazardous chemicals, and operating the instrument in a fume hood.
Detailed procedure for measuring samples using spindles, including sample vessel and spindle positioning.
Procedure for measuring samples using DIN systems, including mounting the DIN adapter and cup.
Steps to start and monitor a measurement, and how the display changes during the process.
Safety measures for using cleaning liquids and handling parts, including protective equipment.
Accessing software maintenance functions like TruSine check, updates, and system information.
A list of common error and warning codes encountered during ViscoQC operation, with descriptions and recommended actions.