10
Red indicator of “Paper Out ” is the paper out indicator. When there is no paper
in printer head, it will light, and it is off under normal status.
2.5 Self-test
The self-test will check the condition of printer, if the printer prints out the
self-test receipt correctly, it means the printer works normally, except interface
with host. Otherwise it needs to repair. The self-test will print out 96 ANK
characters, default code page, name of Chinese Character library, interface
setting and software version.
Way of self-test: hold downFEEDbutton and turn on the power, self-test
begins automatically at this moment.
2.6 Hexadecimal Printing
Turn on the printer according to the step below, it will enter the mode of
Hexadecimal Printing.
1.Open the cover
2.Hold downFEEDbutton,and connect with power
3.Close the cover, the printer will print out 3 lines as below:
Hexadecimal Dump
To terminate hexadecimal dump,
Press FEED button three times.
This means the printer has entered hexadecimal printing mode, and under this
mode, all of the input will be printed out as
hexadecimal number, feed one line with single-click of “FEED” button, after 3
times, it will print out “*** Completed ***”,and exit hexadecimal printing
mode.
2.7 Parameter Setting
This function is for the setting of printer parameters.
Steps for setting parameters:
When printer power is off, open paper case cover firstly. Hold theFEED
button, then switch on the printer and release theFEEDwhen the status
indicator and paper-out indicator flash alternately. Then press the FEED
twice and close the paper cover, printer enter the setting mode and print out
the first set parameter and its default value. The details method of setting
parameter can refer to Appendix A.