7.4. INSTALLATION ON SEGMENTED RADIATORS
7.4.1. Description of installation
E-ITN 40 back plate should be installed on the radiator with clamps and bolts as follows:
place back plate into the final location and fix with clamp and bolt through the centre hole,
tighten to a torque 1 Nm,
place the allocator into the back plate profile groove from top, align it with the base plate and push
allocator to connect it with the back plate.
When using cast iron radiator with a very rough surface (large grain) it is recommended to grind off these
grains at the place where back plate will be installed.
After installation, installation protocol has to be filled up (including date of installation, room, type of the
radiator, allocator serial number, etc.).
7.4.2. Installation differences
a) When installing on the radiators with difficult access (KALOR 3,TERMO) follow these steps:
insert the mounting bolt through centre hole of the back plate and screw it on several threads to
the clamp,
slide prepared set from the top between radiator segments (clamp is in upright position) and
place in the mounting height,
tighten the back plate to a torque 1 Nm.
b) For installation on radiators with larger distance between the segments (Svratouch radiator):
use clamp IV and insert the spacer 45 under E-ITN 40 back plate.
c) For radiators with solid and long cells, as KUVAL radiators:
use a screw with a length 80 mm.
20 / 22