E-ITN 40
Manual for installation service and operation M2021/8a EN
7.5. INSTALLATION ON PANEL RADIATORS
7.5.1. Description of installation
E-ITN 40 back plate should be installed on the panel radiators with two welded bolts thread M3 and
special nuts as follows:
• mark the place for both welding bolts on the radiator,
• remove the paint within the diameter of 10 mm on the marked places,
• weld the bolts to the radiator with two-head welding pistol,
• if one-head welding pistol is used, second bolt have to be in distance 39±1 mm towards the upper
edge of the radiator, remove the paint within the diameter of 10 mm on the marked place,
• attach back plate to the bolts and than to the radiator, screw the nuts to the bolts with socket wrench
M7,
• tighten the nuts to a torque 1 Nm,
• place the allocator into the back plate profile groove from top, align it with the base plate and push
allocator to connect it with the back plate.
After installation, installation protocol have to be filled up (including date of installation, room, type of the
radiator, allocator serial number, etc.)
Warning!
Televisions or other devices with screen must be apart at least 2-3 meters from the place welding.
Devices must be switched off and disconnected from electrical network. Shock during welding can
negatively affect pacemaker. It is necessary to warn the user and explain him requirement of his
absence during installation.
21 / 22