EasyManua.ls Logo

Apator Metra E-ITN 40 - Page 4

Apator Metra E-ITN 40
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E-ITN 40
Manual for installation service and operation M2021/8a EN
W-MBus encrypted
W-MBus OMS
W-MBus OMS encrypted
Allocator is equipped with mechanic and electronic seal and is delivered in sealed state with activated
electronic seal. In the case of unauthorized removing of base plate, the allocator saves the date of breach of
the electronic seal to its memory and stop to show measured data on the display. After each press of button
it is displayed oPEn and after that a menu item. Allocator continues in measuring and transmitting of
measured data.
Notice oPEn will disappear when electronic seal is activated again with NFC.
The device is resistant against cheating. If any cheating is detected, allocator switches to the mode
inconvenient for the user – after cheating is finished, the allocator switches to standard mode.
Allocator can work in mode of individual or unified scale. For correct evaluation it is necessary to use
individual scale:
power of radiator
coefficient (K
C
) taking into consideration heat transfer from radiator to temperature sensor
For unified scale:
Power of radiator and coefficient is always the same.
Parameters can be set beforehand in production or before installation using radio or NFC.
All parameters you can set using application Radio Admin:
Measuring
Count in summer
Power of radiator
Coefficient Kc
Start of heating season
Start of summer season
Start of billing period
Menu (LCD)
Radiator power
Coefficinet Kc
Current temperature of radiator sensor
Current temperature of environment
Maximum temperature of radiator sensor for past yearly billing period
Maximum temperature of radiator sensor for past monthly billing period
Average temperature of radiator sensor for past yearly billing period
Average temperature of radiator sensor for past monthly billing period
Date
Time
Total consumption
Reading and setting of allocator is done using application Radio Admin for smartphones with system Android.
Application can be downloaded in Google Play Store.
4 / 22