7
Regeneration & Error Screens, Button Operation & Function
Regen Screen
Displays the time remaining in the current cycle.
Pressing REGEN advances to the next cycle.
Error Screen
Alternated flashing Err and error code every 3 seconds.
Clear by disconnecting the power supply at the PC
board and reconnecting, or press NEXT and REGEN
simultaneously for 3 seconds.
Changes variable are displayed.
Key sequence to lock and
unlock program settings.
Holding for 3 seconds initiates a control
reset. The software version is displayed
and the piston returns to the home/service position,
resynchronizing the valve.
Used with valve type 1.0
, holding for
at least 3 seconds causes a switch in
the tank in Service without cycling the
regeneration valve. After tank switch, days remaining and
capacity remaining status is retained for each tank until
the next regeneration.
Button Operation and Function
Scrolls to the next display.
Pressing once and releasing will schedule
a regeneration at the preset delayed
regeneration time.
Pressing again and releasing will cancel the regeneration.
Pressing and holding for 3 seconds will initiate an
immediate regeneration.
Pressing while in regeneration will advance to the
next cycle.
Pressing in the program levels will go backwards to
the previous screen.
Manual Regeneration
Normally, you don’t need to perform regeneration after installation, please follow the two steps below in case manual
regeneration is needed.
1. Pressing and releasing the REGEN button. “ REGEN TODAY” will flash on the display and the regeneration
will occur at the delayed regeneration time. The user can cancel the request by pressing and releasing the
REGEN button.
2. Pressing & holding the
REGEN button
for approximately 3 seconds will immediately start the regeneration. The
user cannot cancel this request, except by resetting the control by pressing
NEXT
and
REGEN
simultaneously
for 3 seconds.
In Alternator Systems when a
unit is waiting to initiate the
first cycle step of regeneration,
“REGEN Pndg” is displayed.
“STbY” is displayed in Alterna-
tor Systems when a valve is in
Standby state.
“REGEN Pndg RINSE FILL” is
displayed whenever a zero-
capacity tank has transferred
to an off-line state and is currently waiting to initiate
the second portion of a regeneration cycle. Viewed
only when Delayed Rinse and Fill is set to ON.