ANNEX A – AL1206 position and adherence areas on steel deck
1) General principals
a) The module shall adhere at a minimum of 3 adherence lines if the lines are parallel to the
long edge and a minimum of 4 adherence lines if the lines are parallel to the short edge.
b) The maximum distance from the last adherence line to the module edge is 15 cm. Exceptions
can be made up to 40 cm from the edge by overlapping adhesion of 2 modules (see drawing
below).
c) When adhering to the steel deck with penetrating screws, apply EPDM strips above and along
the screws as shown in the drawing below. Make sure to apply the adhesive over and under
the EPDM strip. NOTE that the last 20cm of the adherence lines (close to the module edges)
must be cleared of EPDM and adhere the module directly to the substrate.
2) Reference examples