Solarpaint
AL1206 Installation Manual
14.9.2023
Rev. [B1]
Page 11 of 28
Mechanical installation
1. General
a. Module Substrate interface diagram
b. General design information
AL1206 modules were tested for 2400pa static load and 1000pa dynamic loads per IEC 61215.
All installations must be approved by building engineering authorities, considering the
environmental conditions, and predicted wind uplift, and subjected to local rules and
regulations.
Approved adhesives were tested to a minimum safety factor of 2.5 times the Approved static
load. Adherence conditions and limitations vary per installation site. Please consult with Apollo
technical support for any inquiries.
The module is in compliance with this standard only when the module is mounted in the
manner specified by the mounting instructions. A module with exposed conductive parts is in
compliance with this standard only when it is electrically grounded in accordance with the
manufacturer's instructions and the requirements of the National Electrical Code, ANSI/NFPA
70 (2014-2017).