ECU-C Installation/User Manual
22
5.EMA Manager
For three-phase Microinverter: Please refer to the document
Altenergy_Power_System_Inc.___three_phase_microinverter_11-12.xlsx
on SunSpec website.
https://certifications.sunspec.org/PICS/Altenergy_Power_System_Inc.
___three_phase_microinverter_11-12.xlsx
For single-phase Microinverter: Please refer to the document
Altenergy_Power_System_Inc.___single_phase_MicroinverterAPpcs_11
-12 on SunSpec website.
https://certifications.sunspec.org/PICS/Altenergy_Power_System_Inc.
___single_phase_MicroinverterAPpcs_11-12.xlsx
Click Modbus Settings in the Workspace, switch on the SunSpec
Modbus function. Select the baud rate and configure Inverters
address in the address text box. Finally, click Save to finish
configuration.
The hosts RS485 port must be configured to the same baud rate, 8
data bits, 1 stop bit, none parity bit.
Not compatible with split-phase (2 phases) systems as commonly
used in the Americas.