REMOTE CONTROL is an
OPTION
3.3 – REMOTE CONTROL PANEL (EXTRA)
RE
P.
DES
CRIP
TION
FUNCTION
50 Push button Start Start the unit.
51 Push button Stop Stop the unit.
52 Push button Rinsing Rinse the unit.
53
Indicator lamp
Gree
n led
indicating the unit has started up.
54 Indicator lamp Green led indicating the unit is in rinsing mode.
55 Indicator lamp Green led indicating the unit is producing fresh water towards the storage tank.
These options allows control and surveillance of the AQUA-BASE unit from a remote location (chart table).
(Ref. Remote control: 999155)
Composition.
The remote control is composed of a built-in remote panel and its connecting wire.
Installation.
- Put the remote panel in place, according to the drawing below.
- Plug the connecting wire to the electric box: connector 8P.
- Open the electric box and remove the shunt between terminals 3 and 9 (otherwise it will cause a malfunction of the unit)
- Shut the main electric box.
WARNING: SHUNT BETWEEN TERMINALS 3
-
9
HAS TO BE REMOVED IF
THE
REMOT
E CONTR
O
L
PANEL IS CONNECTED
53
50
51
52
54
55
SHUNT 3
-
9
TO REMOVE
(inside the electric box)