B – THE LP PUMP
1 – LP PUMP INSTALLATION
The booster pump must be installed 200mm below the water line, between the hull valve and the filter 5µ (as indicated in Fig. installation on
board in Appendix). There should be no air accumulation.
Only use the pipe provided by SLCE respecting the diameters and type of hose (see installation drawing board 111121-08).
If the pump is placed too far or too high compared to the hull fitting, cavitation is possible. Cavitation produces jangling that might completely
destroy the pump. The LP pump must be installed horizontally and or vertically (provided it is below the engine).
This type of LP pump prohibits operation without water. The pump must be installed below the water line, between the hull valve
(V0) and the filter 5µ (4).
Some examples of LP pump installation:
- The pump is imperatively at 200 mm below the water line,
- The hull valve (V0) should be placed below the LP pump,
- The rising line should be installed above the LP pump, so as to avoid air accumulation or trapped air.
GOOD INSTALLATION
BAD INSTALLATION
2 – LP PUMP TYPE
Exists differents pumps according to the unit :
Rep
Référence
Dés
ignation
3
605031
656200
656224
605032
605033
6-56.202
6
-
56.203
Booster pump 330L
Electric motor 12VCC-125W
Electric motor 12VCC-150W
Booster pump 660 L
Booster pump 1000 L
Electric motor 12VCC-460W
Electric motor 24VCC
-
550W
A1/A2/
A3/A5
717361
Flexible hose steel 20x27
B1/B2
717303
Flexible 19x27
719234
Straight M 1/2” x 19 ribbed
719242
Splined elbow M 1/2” x 19
The feed-wire is connected in accordance to the electric
diagram in Appendix.
2.1 – MAINTENANCE OF THE PUMP
The only required maintenance of the pump, is to flush it with fresh water during cleaning operation of the unit.
For a long term stop, it is necessary to store the PROCON pump (with glycerin), see Technical Note NT0809 (end of manual).
NB : A rinsing operation of the LP pump-barrel with fresh water before a 3 day operating stop or longer considerably increases the life of the
LP pump.