D5 NEXT
For calibration, the pump has to be operated with blocked coolant flow for a short
period of time. This can be achieved by kinking a hose within the coolant loop or
by closing a ball valve/stop valve installed into the coolant loop.
Calibration process:
1. The system has to be perfectly deaerated, no bubbles or foam visible in the
coolant.
2. Coolant temperature should be between 25 °C and 35 °C.
3. Ensure that the computer is currently idle and no high-load background
tasks are currently active. During calibration, no coolant is pumped through
the system!
4. Block coolant flow by kinking a hose or closing a stop valve in the coolant
loop.
5. Start the calibration process either using the aquasuite or the device menu.
6. Wait for the calibration process to complete. The process takes approxi-
mately 30 seconds. If errors occur or if the calibration process has not fin-
ished after 60 seconds, immediately proceed to the next step.
7. Restore coolant flow. Ensure no hoses are kinked and stop valves if present
are fully opened.
Limitations: Flow rate can not be calculated if a second pump is present in the
cooling circuit! Flow rate calculation is calibrated for DP Ultra viscosity and will
deviate when using other coolants ore pure water!
13.4.
13.4.13.4.
13.4. Mechanical flow sensor
Mechanical flow sensorMechanical flow sensor
Mechanical flow sensor
Calibration values for sensors sold by Aqua Computer can conveniently be select-
ed from a drop-down list. Select the appropriate entry in the “sensor type” selector
for the flow sensor connected to the D5 NEXT.
Connect the flow sensor to the fan output of the D NEXT controller unit. Simultane-
ous connection of fan and flow sensor is not possible. If the connector is to be
used as a fan output, select “virtual flow sensor” as “sensor type”.
If necessary, the flow rate can be calibrated by ±10 %.
13.5.
13.5.13.5.
13.5. Software temperature sensors
Software temperature sensorsSoftware temperature sensors
Software temperature sensors
Software temperature sensors can be used to transfer temperature sensor readings
from the computer to the D5 NEXT by USB connection.
During installation of the aquasuite, the background service “Aqua Computer Ser-
vice” is also installed. This service supplies various data from PC components and
imported data from aquasuite web, additionally sensor data provided by third par-
ty software can be accessed. In order to access third party software data, the third
party software has to be correctly installed, configured and running.
Currently, the “Aqua Computer Service” supports data transfer from “HWiNFO”
(REALiX, Freeware, www.hwinfo.com) and “AIDA64” (FinalWire Ltd., subject to li-
cense fees, www.aida64.com).
- 20 - Aqua Computer GmbH & Co. KG © 2019-2020
Gelliehäuser Str. 1, 37130 Gleichen
c
o
m
p
u
t
e
r
a
q
u
a

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Aqua Computer D5 NEXT and is the answer not in the manual?

Aqua Computer D5 NEXT Specifications

General IconGeneral
BrandAqua Computer
ModelD5 NEXT
CategoryWater Pump
LanguageEnglish