AIR TO WATER POOL HEAT PUMP VERTICLE PH SERIES
5/ 52 VERSION 19 , RELEASE 29th June 2020
The aim of this manual is to provide instructions for installation, commissioning and operation.
WARNING!
The installation, commissioning and maintenance
of the product should be performed by qualified
technicians who have a good knowledge of
standards and local regulations, as well as
experience of this type of equipment.
Take Care!
It is forbidden to start any work on the electrical
components without switching off the electrical
supply to the unit.
WARNING!
The unit must be EARTHED to avoid any risks
caused by insulation defects.
Take Care!
It is forbidden to start any work on the electrical
components if water or high humidity is present at
the installation site.
WARNING!
No wiring must come in contact with the heat
source or the fan rotating parts.
Take Care!
To ensure the unit is running safely, the set water
temperature cannot exceed over 40℃, (105°F).
WARNING!
In preparation for shutting down the unit for a
prolonged period and if the installation does not
contain glycol, the evaporator and the chiller
water pipes need to be carefully and completely
drained of water.
Take Care!
When the unit is being connected, ensure that no
impurities are introduced into the pipe work and
the water circuits.
WARNING!
When shutting down the unit for a prolonged
period the condenser and the chilled water pipes
on the reversible unit need to be carefully flushed
with fresh water (for 15 minutes by the outlet) and
then completely drained of water.
Take Care!
An insulated pipe for protection must be used for
the 3-core signal wire outlet for outdoor
installation.
WARNING!
Any wiring produced on site must comply with
local electrical regulations.
Take Care!
Use Copper supply wires.
WARNING!
Ensure that the electrical supply corresponds to
the specification indicated on the manufacturer
unit plate before proceeding with the connection
and it is in accordance with the wiring diagram
supplied.
Take Care!
The unit should be handled using lifting end
handling equipment appropriate to the unit’s size
and weight.
The manufacturer's warranty will not apply if the installation recommendations listed in
this manual are not followed.
2. SPECIFICATIONS
2.1 Performance and Features
• High efficiency
With a COP value of up to 5.0 our heat pumps are very efficient when transferring heat from the air to
the swimming pool water. There is a cost saving of up to 80% compared to an electrical heater.
• Long lifespan
The heat exchanger is made of PVC and Titanium tube, which can withstand prolong exposure to
swimming pool water.
• Easy control and operation