AIR TO WATER POOL HEAT PUMP VERTICLE PH SERIES
25/ 52 VERSION 19 , RELEASE 29th June 2020
25
/
52
Manufacturer default
Channel
Parameter name
Adjustment range
Initial value
///
Pool water temperature
L1
Pool water temperature display deviation value
0─15
0
L2
Compressor starts with the set temperature deviation
1─15
2
L3
Water pump run mode
0~120 min
30
L4
Set max. temperature
1080
34
L5
Allow the auxiliary heating of the ambient temp. on
0─35
0
L6
Reserved parameter
/
/
L7
Reserved parameter
/
/
L8
Compressor current protection settings
0-33A
0
L9
Fan for low speed when the ambient temperature set
1065
26
LA
The mode of water pump
0-65
LA=0,
compressor
turn off
water pump
turn off with
deferred
LA=1
Compressor
turn off,
water pump
never stop
to work
LA=2
Compressor
turn off ,
water pump
each
30mins start
2mins to
work.