Shower head systems installation instructions Page 11
Drill a hole (minimum ø28mm, maximum ø40mm) through the ceiling and the noggin.
3
Remove the fixing bracket carefully from the fixed head arm.
4
Set the fixing bracket into position and mark the fixing points. Remove
the bracket and drill and prepare suitable fixings. Refit the fixing
bracket and secure it through the ceiling and into the noggin using
the screws provided if suitable.
5
Feed the arm through the fixing bracket to the correct depth.
Tighten the nut using a 32mm spanner if necessary to facilitate.
6
Cut off the excess pipe allowing for a suitable working length to allow for the required 22mm
connection. If a push fit connector is to be used then the pipe must be abraded to remove all
chrome plating.
7
Connect the pipe work from the valve, diverter or processor to the end of the fixed head
pipe using a suitable coupling.
8
Run the shower for a few seconds to clear any debris and to check for any leaks.
!